Skip to main content
Journal cover image

Downstream clinical consequences of stress cardiovascular magnetic resonance based on appropriate use criteria.

Publication ,  Journal Article
McGraw, S; Mirza, O; Bauml, MA; Rangarajan, VS; Farzaneh-Far, A
Published in: J Cardiovasc Magn Reson
May 15, 2015

BACKGROUND: Appropriate use criteria (AUC) have been developed by professional organizations as a response to the rising costs of imaging, with the goal of optimizing test-patient selection. Consequently, the AUC are now increasingly used by third-party-payers to assess reimbursement. However, these criteria were created by expert consensus and have not been systematically assessed for CMR. The aim of this study was to determine the rates of abnormal stress-CMR and subsequent downstream utilization of angiography and revascularization procedures based on the most recent AUC. METHODS: 300 consecutive patients referred for CMR-stress testing were prospectively enrolled. Two cardiologists reviewed all clinical information before the CMR-stress test and classified the test as "appropriate', "maybe appropriate" or "rarely appropriate" according to the 2013 AUC. Patients were followed for 2 months for the primary outcomes of coronary angiography and/or revascularization. RESULTS: 49.7% of stress CMRs were appropriate, 36.7% maybe appropriate, and 13.6% rarely appropriate. Ischemia was significantly more likely to be seen in the appropriate (18.8%) or maybe appropriate groups (21.8%) than the rarely appropriate group (4.8%) (p = 0.030 and p = 0.014 respectively). Referral for cardiac catheterization was not significantly different in the appropriate (10.1%) and maybe appropriate groups (10.0%) compared to the rarely appropriate group (2.4%) (p = 0.119 and p = 0.127 respectively). No patients undergoing catheterization in the rarely appropriate group went on to require revascularization, in contrast to 53.3% of the appropriate vs 36.4% of the maybe appropriate patients (p = 0.391). Presence of ischemia led to referral for cardiac catheterization in 50.0% of the appropriate group vs 33.3% of the maybe appropriate group (p = 0.225); in contrast to none of the rarely appropriate group. CONCLUSIONS: The great majority of tests were classified as appropriate or maybe appropriate. Downstream cardiac catheterization rates were similar in all 3 groups. However, rarely appropriate studies never required revascularization, suggesting suboptimal resource utilization. Studies classified as maybe appropriate had similar rates of abnormal findings and led to similar rates of downstream catheterization and revascularization as those that were deemed appropriate. This suggests that consideration could be given to upgrading some of the common maybe appropriate indications to the appropriate category.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

J Cardiovasc Magn Reson

DOI

EISSN

1532-429X

Publication Date

May 15, 2015

Volume

17

Issue

1

Start / End Page

35

Location

England

Related Subject Headings

  • Unnecessary Procedures
  • Referral and Consultation
  • Prospective Studies
  • Predictive Value of Tests
  • Practice Patterns, Physicians'
  • Practice Guidelines as Topic
  • Patient Selection
  • Nuclear Medicine & Medical Imaging
  • Myocardial Revascularization
  • Middle Aged
 

Citation

APA
Chicago
ICMJE
MLA
NLM
McGraw, S., Mirza, O., Bauml, M. A., Rangarajan, V. S., & Farzaneh-Far, A. (2015). Downstream clinical consequences of stress cardiovascular magnetic resonance based on appropriate use criteria. J Cardiovasc Magn Reson, 17(1), 35. https://doi.org/10.1186/s12968-015-0137-x
McGraw, Sloane, Omer Mirza, Michael A. Bauml, Vibhav S. Rangarajan, and Afshin Farzaneh-Far. “Downstream clinical consequences of stress cardiovascular magnetic resonance based on appropriate use criteria.J Cardiovasc Magn Reson 17, no. 1 (May 15, 2015): 35. https://doi.org/10.1186/s12968-015-0137-x.
McGraw S, Mirza O, Bauml MA, Rangarajan VS, Farzaneh-Far A. Downstream clinical consequences of stress cardiovascular magnetic resonance based on appropriate use criteria. J Cardiovasc Magn Reson. 2015 May 15;17(1):35.
McGraw, Sloane, et al. “Downstream clinical consequences of stress cardiovascular magnetic resonance based on appropriate use criteria.J Cardiovasc Magn Reson, vol. 17, no. 1, May 2015, p. 35. Pubmed, doi:10.1186/s12968-015-0137-x.
McGraw S, Mirza O, Bauml MA, Rangarajan VS, Farzaneh-Far A. Downstream clinical consequences of stress cardiovascular magnetic resonance based on appropriate use criteria. J Cardiovasc Magn Reson. 2015 May 15;17(1):35.
Journal cover image

Published In

J Cardiovasc Magn Reson

DOI

EISSN

1532-429X

Publication Date

May 15, 2015

Volume

17

Issue

1

Start / End Page

35

Location

England

Related Subject Headings

  • Unnecessary Procedures
  • Referral and Consultation
  • Prospective Studies
  • Predictive Value of Tests
  • Practice Patterns, Physicians'
  • Practice Guidelines as Topic
  • Patient Selection
  • Nuclear Medicine & Medical Imaging
  • Myocardial Revascularization
  • Middle Aged