Skip to main content
Journal cover image

Prognostic value of the cadmium-zinc-telluride camera: A comparison with a conventional (Anger) camera.

Publication ,  Journal Article
Oldan, JD; Shaw, LK; Hofmann, P; Phelan, M; Nelson, J; Pagnanelli, R; Borges-Neto, S
Published in: J Nucl Cardiol
December 2016

BACKGROUND: New multipinhole cadmium-zinc-telluride (CZT) cameras allow for faster imaging and lower radiation doses for single photon emission computed tomography (SPECT) studies, but assessment of prognostic ability is necessary. METHODS AND RESULTS: We collected data from all myocardial SPECT perfusion studies performed over 15 months at our institution, using either a CZT or conventional Anger camera. A Cox proportional hazards model was used to assess the relationship between camera type, imaging results, and either death or myocardial infarction (MI). Clinical variables including age, sex, body mass index (BMI), and historical risk factors were used for population description and model adjustments. We had 2,088 patients with a total of 69 deaths and 65 MIs (122 events altogether). A 3% increase in DDB (difference defect burden) represented a 12% increase in the risk of death or MI, whereas a 3% increase in rest defect burden or stress defect burden represented an 8% increase; these risks were the same for both cameras (P > .24, interaction tests). CONCLUSIONS: The CZT camera has similar prognostic values for death and MI to conventional Anger cameras. This suggests that it may successfully be used to decrease patient dose.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

J Nucl Cardiol

DOI

EISSN

1532-6551

Publication Date

December 2016

Volume

23

Issue

6

Start / End Page

1280 / 1287

Location

United States

Related Subject Headings

  • Zinc
  • Young Adult
  • Tomography, Emission-Computed, Single-Photon
  • Tellurium
  • Survival Analysis
  • Sex Distribution
  • Sensitivity and Specificity
  • Risk Assessment
  • Reproducibility of Results
  • Prognosis
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Oldan, J. D., Shaw, L. K., Hofmann, P., Phelan, M., Nelson, J., Pagnanelli, R., & Borges-Neto, S. (2016). Prognostic value of the cadmium-zinc-telluride camera: A comparison with a conventional (Anger) camera. J Nucl Cardiol, 23(6), 1280–1287. https://doi.org/10.1007/s12350-015-0181-9
Oldan, Jorge Daniel, Linda K. Shaw, Paul Hofmann, Matthew Phelan, Jeffrey Nelson, Robert Pagnanelli, and Salvador Borges-Neto. “Prognostic value of the cadmium-zinc-telluride camera: A comparison with a conventional (Anger) camera.J Nucl Cardiol 23, no. 6 (December 2016): 1280–87. https://doi.org/10.1007/s12350-015-0181-9.
Oldan JD, Shaw LK, Hofmann P, Phelan M, Nelson J, Pagnanelli R, et al. Prognostic value of the cadmium-zinc-telluride camera: A comparison with a conventional (Anger) camera. J Nucl Cardiol. 2016 Dec;23(6):1280–7.
Oldan, Jorge Daniel, et al. “Prognostic value of the cadmium-zinc-telluride camera: A comparison with a conventional (Anger) camera.J Nucl Cardiol, vol. 23, no. 6, Dec. 2016, pp. 1280–87. Pubmed, doi:10.1007/s12350-015-0181-9.
Oldan JD, Shaw LK, Hofmann P, Phelan M, Nelson J, Pagnanelli R, Borges-Neto S. Prognostic value of the cadmium-zinc-telluride camera: A comparison with a conventional (Anger) camera. J Nucl Cardiol. 2016 Dec;23(6):1280–1287.
Journal cover image

Published In

J Nucl Cardiol

DOI

EISSN

1532-6551

Publication Date

December 2016

Volume

23

Issue

6

Start / End Page

1280 / 1287

Location

United States

Related Subject Headings

  • Zinc
  • Young Adult
  • Tomography, Emission-Computed, Single-Photon
  • Tellurium
  • Survival Analysis
  • Sex Distribution
  • Sensitivity and Specificity
  • Risk Assessment
  • Reproducibility of Results
  • Prognosis