Skip to main content

SU-D-BRA-01: Therapeutic Response Assessment Using a Novel Gray Level Local Power Matrix (GLLPM) in DCE-MRI Texture Analysis: Feasibility Study.

Publication ,  Journal Article
Wang, C; Subashi, E; Yin, F; Chang, Z
Published in: Med Phys
June 2015

PURPOSE: Most current DCE-MRI texture analysis methods focus on the spatial information of chosen contrast-enhanced MR volumes or pharmacokinetic (PK) parameter maps, and the temporal information is not well included. This work proposed a novel texture matrix called Gray Level Local Power Matrix (GLLPM) for the accurate and efficient spatiotemporal DCE-MRI texture analysis in therapeutic response assessment. METHODS: A retrospective study with two groups (n=8/group) of tumor implanted mice was conducted. The treatment/control groups received bevacizumab/saline treatment with pre- and post-treatment DCE-MRI exams. For each scan, the GLLPM was calculated and compared with classic 3D/4D Gray Level Co-Occurrence Matrices (GLCOM) using the CA concentration maps in the first 10-minute post-injection time. The calculation time of each matrix was recorded for efficiency evaluation. Using each matrix, a set of 22 Haralick texture features' dynamic curves were calculated. The Mann-Whitney U-test was used to assess the differences of the Area Under Curve (AUC) of all derived texture feature curves between treatment/control groups. The post-treatment texture feature curves were fitted by cubic polynomial. Experiments using support vector machine in a leave-one-out approach were performed to validate the use of fitted polynomial coefficients of each texture feature curve in treatment/control group classification. RESULTS: The computation efficiency of GLLPM had improved factors of 3 and 20 in comparison with 3D/4D GLCOM, respectively. 21 out of 22 GLLPM texture feature dynamic curves' AUCs between treatment/control groups had significant differences in post-treatment scan but not in pre-treatment scan. N=19 dynamic curves from GLLPM can be fitted by cubic polynomial (R(2)>0.8), and N for 3D/4D GLCOM were 14 and 19, respectively. The averaged classification accuracies using the post-treatment texture features curves based on GLLPM, 3D/4D GLCOM were (84.5±12.1)%, (65.6±10.5)% and (73.3±12.8)%, respectively. CONCLUSION: The proposed GLLPM and its features can be used for the efficient DCE-MRI therapeutic response assessment.

Duke Scholars

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

June 2015

Volume

42

Issue

6

Start / End Page

3212

Location

United States

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

June 2015

Volume

42

Issue

6

Start / End Page

3212

Location

United States

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences