Skip to main content

Radiological protection in computed tomography and cone beam computed tomography.

Publication ,  Journal Article
Rehani, MM
Published in: Ann ICRP
June 2015

The International Commission on Radiological Protection (ICRP) has sustained interest in radiological protection in computed tomography (CT), and ICRP Publications 87 and 102 focused on the management of patient doses in CT and multi-detector CT (MDCT) respectively. ICRP forecasted and 'sounded the alarm' on increasing patient doses in CT, and recommended actions for manufacturers and users. One of the approaches was that safety is best achieved when it is built into the machine, rather than left as a matter of choice for users. In view of upcoming challenges posed by newer systems that use cone beam geometry for CT (CBCT), and their widened usage, often by untrained users, a new ICRP task group has been working on radiological protection issues in CBCT. Some of the issues identified by the task group are: lack of standardisation of dosimetry in CBCT; the false belief within the medical and dental community that CBCT is a 'light', low-dose CT whereas mobile CBCT units and newer applications, particularly C-arm CT in interventional procedures, involve higher doses; lack of training in radiological protection among clinical users; and lack of dose information and tracking in many applications. This paper provides a summary of approaches used in CT and MDCT, and preliminary information regarding work just published for radiological protection in CBCT.

Duke Scholars

Published In

Ann ICRP

DOI

EISSN

1872-969X

Publication Date

June 2015

Volume

44

Issue

1 Suppl

Start / End Page

229 / 235

Location

England

Related Subject Headings

  • Tomography, X-Ray Computed
  • Radiometry
  • Radiation Protection
  • Radiation Dosage
  • Nuclear Medicine & Medical Imaging
  • Humans
  • Health Knowledge, Attitudes, Practice
  • Cone-Beam Computed Tomography
  • 1103 Clinical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Rehani, M. M. (2015). Radiological protection in computed tomography and cone beam computed tomography. Ann ICRP, 44(1 Suppl), 229–235. https://doi.org/10.1177/0146645315575872
Rehani, M. M. “Radiological protection in computed tomography and cone beam computed tomography.Ann ICRP 44, no. 1 Suppl (June 2015): 229–35. https://doi.org/10.1177/0146645315575872.
Rehani, M. M. “Radiological protection in computed tomography and cone beam computed tomography.Ann ICRP, vol. 44, no. 1 Suppl, June 2015, pp. 229–35. Pubmed, doi:10.1177/0146645315575872.

Published In

Ann ICRP

DOI

EISSN

1872-969X

Publication Date

June 2015

Volume

44

Issue

1 Suppl

Start / End Page

229 / 235

Location

England

Related Subject Headings

  • Tomography, X-Ray Computed
  • Radiometry
  • Radiation Protection
  • Radiation Dosage
  • Nuclear Medicine & Medical Imaging
  • Humans
  • Health Knowledge, Attitudes, Practice
  • Cone-Beam Computed Tomography
  • 1103 Clinical Sciences