Skip to main content
Journal cover image

A comparison of the relative risk of vessel injury with conical versus pyramidal laparoscopic trocars in a rabbit model.

Publication ,  Journal Article
Hurd, WW; Wang, L; Schemmel, MT
Published in: Am J Obstet Gynecol
December 1995

OBJECTIVE: Our purpose was to compare the relative risk of vessel injury after use of a 5 mm conical-tipped trocar, a 5 mm pyramidal-tipped trocar, and a 10 mm pyramidal-tipped trocar in a rabbit vessel model. STUDY DESIGN: Plastic templates were placed in front of and behind 108 mesenteric vessels in 11 anesthetized New Zealand White rabbits. Laparoscopic trocars were inserted through the templates and mesentery. The incidence of vessel injury was determined at distances from the vessels ranging from 0 to 5 mm. RESULTS: The 5 mm conical trocar resulted in a vessel injury rate of 88% at 0 mm from the vessel but 0% at 1 or 2 mm. The 5 mm pyramidal trocar resulted in 100%, 88%, and 62% injury rates of 0, 1, and 2 mm from the vessels, respectively. The 10 mm pyramidal trocar resulted in a 100% injury rate at 0, 1, 2, or 3 mm from the vessels and 80% and 40% at 4 mm and 5mm, respectively. CONCLUSION: The relative risk of vessel injury is significantly increased by the use of pyramidal-tipped trocars when compared with conical-tipped trocars, especially if larger diameter trocars are used.

Duke Scholars

Published In

Am J Obstet Gynecol

DOI

ISSN

0002-9378

Publication Date

December 1995

Volume

173

Issue

6

Start / End Page

1731 / 1733

Location

United States

Related Subject Headings

  • Surgical Instruments
  • Risk Factors
  • Rabbits
  • Obstetrics & Reproductive Medicine
  • Laparoscopes
  • Disease Models, Animal
  • Blood Vessels
  • Animals
  • 1114 Paediatrics and Reproductive Medicine
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Hurd, W. W., Wang, L., & Schemmel, M. T. (1995). A comparison of the relative risk of vessel injury with conical versus pyramidal laparoscopic trocars in a rabbit model. Am J Obstet Gynecol, 173(6), 1731–1733. https://doi.org/10.1016/0002-9378(95)90418-2
Hurd, W. W., L. Wang, and M. T. Schemmel. “A comparison of the relative risk of vessel injury with conical versus pyramidal laparoscopic trocars in a rabbit model.Am J Obstet Gynecol 173, no. 6 (December 1995): 1731–33. https://doi.org/10.1016/0002-9378(95)90418-2.
Hurd, W. W., et al. “A comparison of the relative risk of vessel injury with conical versus pyramidal laparoscopic trocars in a rabbit model.Am J Obstet Gynecol, vol. 173, no. 6, Dec. 1995, pp. 1731–33. Pubmed, doi:10.1016/0002-9378(95)90418-2.
Hurd WW, Wang L, Schemmel MT. A comparison of the relative risk of vessel injury with conical versus pyramidal laparoscopic trocars in a rabbit model. Am J Obstet Gynecol. 1995 Dec;173(6):1731–1733.
Journal cover image

Published In

Am J Obstet Gynecol

DOI

ISSN

0002-9378

Publication Date

December 1995

Volume

173

Issue

6

Start / End Page

1731 / 1733

Location

United States

Related Subject Headings

  • Surgical Instruments
  • Risk Factors
  • Rabbits
  • Obstetrics & Reproductive Medicine
  • Laparoscopes
  • Disease Models, Animal
  • Blood Vessels
  • Animals
  • 1114 Paediatrics and Reproductive Medicine