Skip to main content
construction release_alert
Scholars@Duke will be undergoing maintenance April 11-15. Some features may be unavailable during this time.
cancel
Journal cover image

Investigation of electrospray ionization and electrostatic focusing devices using a three-dimensional electrospray current density profiler

Publication ,  Journal Article
Thompson, JW; Eschelbach, JW; Wilburn, RT; Jorgenson, JW
Published in: Journal of the American Society for Mass Spectrometry
March 1, 2005

A novel instrument for profiling the current density of nanoelectrospray ionization plumes in three dimensions has been developed. A hemispherically- shaped electrostatic lens at atmospheric pressure is found to be able to compress the space-charge in nano-ESI and increase the average current density in the plume to three times the nominal value. Ion transmission into a single-quadrupole mass spectrometer is found to roughly double using the electrostatic lens. Data also suggest that ion transmission into the first vacuum region for a skimmer-type mass spectrometer interface using nano-ESI may be typically 40% or better with no special focusing device used. © 2004 American Society for Mass Spectrometry.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Journal of the American Society for Mass Spectrometry

DOI

ISSN

1044-0305

Publication Date

March 1, 2005

Volume

16

Issue

3

Start / End Page

312 / 323

Related Subject Headings

  • Analytical Chemistry
  • 3401 Analytical chemistry
  • 0306 Physical Chemistry (incl. Structural)
  • 0304 Medicinal and Biomolecular Chemistry
  • 0301 Analytical Chemistry
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Thompson, J. W., Eschelbach, J. W., Wilburn, R. T., & Jorgenson, J. W. (2005). Investigation of electrospray ionization and electrostatic focusing devices using a three-dimensional electrospray current density profiler. Journal of the American Society for Mass Spectrometry, 16(3), 312–323. https://doi.org/10.1016/j.jasms.2004.11.012
Thompson, J. W., J. W. Eschelbach, R. T. Wilburn, and J. W. Jorgenson. “Investigation of electrospray ionization and electrostatic focusing devices using a three-dimensional electrospray current density profiler.” Journal of the American Society for Mass Spectrometry 16, no. 3 (March 1, 2005): 312–23. https://doi.org/10.1016/j.jasms.2004.11.012.
Thompson JW, Eschelbach JW, Wilburn RT, Jorgenson JW. Investigation of electrospray ionization and electrostatic focusing devices using a three-dimensional electrospray current density profiler. Journal of the American Society for Mass Spectrometry. 2005 Mar 1;16(3):312–23.
Thompson, J. W., et al. “Investigation of electrospray ionization and electrostatic focusing devices using a three-dimensional electrospray current density profiler.” Journal of the American Society for Mass Spectrometry, vol. 16, no. 3, Mar. 2005, pp. 312–23. Scopus, doi:10.1016/j.jasms.2004.11.012.
Thompson JW, Eschelbach JW, Wilburn RT, Jorgenson JW. Investigation of electrospray ionization and electrostatic focusing devices using a three-dimensional electrospray current density profiler. Journal of the American Society for Mass Spectrometry. 2005 Mar 1;16(3):312–323.
Journal cover image

Published In

Journal of the American Society for Mass Spectrometry

DOI

ISSN

1044-0305

Publication Date

March 1, 2005

Volume

16

Issue

3

Start / End Page

312 / 323

Related Subject Headings

  • Analytical Chemistry
  • 3401 Analytical chemistry
  • 0306 Physical Chemistry (incl. Structural)
  • 0304 Medicinal and Biomolecular Chemistry
  • 0301 Analytical Chemistry