Skip to main content
Journal cover image

Prognostic usefulness of insulin-like growth factor-binding protein 7 in heart failure with reduced ejection fraction: a novel biomarker of myocardial diastolic function?

Publication ,  Journal Article
Gandhi, PU; Gaggin, HK; Sheftel, AD; Belcher, AM; Weiner, RB; Baggish, AL; Motiwala, SR; Liu, PP; Januzzi, JL
Published in: Am J Cardiol
November 15, 2014

Insulin-like growth factor-binding protein 7 (IGFBP7) is a biomarker that has recently been associated with heart failure and cardiac hypertrophy. The aim of this study was to examine IGFBP7 relative to echocardiographic abnormalities reflecting diastolic dysfunction. One hundred twenty-four patients with ambulatory heart failure with reduced ejection fraction and baseline detailed 2-dimensional echocardiograms were followed for a mean of 10 months. IGFBP7 was measured serially at each office visit; 108 patients underwent follow-up echocardiography. Echocardiographic parameters of diastolic function were compared at baseline and over time. IGFBP7 concentrations were not linked to left ventricular size or systolic function. In contrast, those with elevated baseline IGFBP7 concentrations were more likely to have abnormalities of parameters describing diastolic function, such as higher left atrial volume index, transmitral E/A ratio, E/E' ratio, and right ventricular systolic pressure. IGFBP7 was correlated with left atrial volume index (ρ = 0.237, p = 0.008), transmitral E/A ratio (ρ = 0.304, p = 0.001), E/E' ratio (ρ = 0.257, p = 0.005), and right ventricular systolic pressure (ρ = 0.316, p = 0.001). Furthermore, each was found to be independently predictive of IGFBP7 in adjusted analysis. In subjects with baseline and final echocardiograms, more time spent with elevated IGFBP7 concentrations in serial measurement was associated with worsening diastolic function and increasing left atrial volume index or right ventricular systolic pressure. IGFBP7 concentrations were predictive of an increased risk for cardiovascular events independent of echocardiographic measures of diastolic function (p = 0.006). In conclusion, IGFBP7 is a novel prognostic biomarker for heart failure with reduced ejection fraction and shows significant links to the presence and severity of echocardiographic parameters of abnormal diastolic function.

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Am J Cardiol

DOI

EISSN

1879-1913

Publication Date

November 15, 2014

Volume

114

Issue

10

Start / End Page

1543 / 1549

Location

United States

Related Subject Headings

  • Ventricular Function, Left
  • Time Factors
  • Stroke Volume
  • Severity of Illness Index
  • Prospective Studies
  • Prognosis
  • Myocardial Contraction
  • Middle Aged
  • Male
  • Insulin-Like Growth Factor Binding Proteins
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Gandhi, P. U., Gaggin, H. K., Sheftel, A. D., Belcher, A. M., Weiner, R. B., Baggish, A. L., … Januzzi, J. L. (2014). Prognostic usefulness of insulin-like growth factor-binding protein 7 in heart failure with reduced ejection fraction: a novel biomarker of myocardial diastolic function? Am J Cardiol, 114(10), 1543–1549. https://doi.org/10.1016/j.amjcard.2014.08.018
Gandhi, Parul U., Hanna K. Gaggin, Alex D. Sheftel, Arianna M. Belcher, Rory B. Weiner, Aaron L. Baggish, Shweta R. Motiwala, Peter P. Liu, and James L. Januzzi. “Prognostic usefulness of insulin-like growth factor-binding protein 7 in heart failure with reduced ejection fraction: a novel biomarker of myocardial diastolic function?Am J Cardiol 114, no. 10 (November 15, 2014): 1543–49. https://doi.org/10.1016/j.amjcard.2014.08.018.
Gandhi PU, Gaggin HK, Sheftel AD, Belcher AM, Weiner RB, Baggish AL, et al. Prognostic usefulness of insulin-like growth factor-binding protein 7 in heart failure with reduced ejection fraction: a novel biomarker of myocardial diastolic function? Am J Cardiol. 2014 Nov 15;114(10):1543–9.
Gandhi, Parul U., et al. “Prognostic usefulness of insulin-like growth factor-binding protein 7 in heart failure with reduced ejection fraction: a novel biomarker of myocardial diastolic function?Am J Cardiol, vol. 114, no. 10, Nov. 2014, pp. 1543–49. Pubmed, doi:10.1016/j.amjcard.2014.08.018.
Gandhi PU, Gaggin HK, Sheftel AD, Belcher AM, Weiner RB, Baggish AL, Motiwala SR, Liu PP, Januzzi JL. Prognostic usefulness of insulin-like growth factor-binding protein 7 in heart failure with reduced ejection fraction: a novel biomarker of myocardial diastolic function? Am J Cardiol. 2014 Nov 15;114(10):1543–1549.
Journal cover image

Published In

Am J Cardiol

DOI

EISSN

1879-1913

Publication Date

November 15, 2014

Volume

114

Issue

10

Start / End Page

1543 / 1549

Location

United States

Related Subject Headings

  • Ventricular Function, Left
  • Time Factors
  • Stroke Volume
  • Severity of Illness Index
  • Prospective Studies
  • Prognosis
  • Myocardial Contraction
  • Middle Aged
  • Male
  • Insulin-Like Growth Factor Binding Proteins