Measurement of angiotensin II: use of two injectors to minimize HPLC shadowing.

Publication ,  Journal Article
Naik, GO; Forster, C; Armstrong, PW
Published in: Peptides
1994

We investigated the use of two HPLC injectors, one reserved for standards and the other for blanks or biological samples, to minimize shadowing in the measurement of angiotensin II (ANGII). HPLC carryover of standard ANGII to blank with a one-injector and a two-injector system were 47.0 +/- 5.0 and 2.4 +/- 0.5 fmol/ml, respectively, a 19.6-fold reduction. Measured normal canine left ventricular myocardium ANGII level by the two-injector HPLC-RIA system was 22.3 +/- 2.4 fmol/g, with a signal-to-noise ratio of 11.7, an improved signal-to-noise ratio of 29.3 fold vs. the one injector. This innovation reduced the incidence of false-positive ANGII results, and thus can be applied to other compounds that exhibit HPLC-derived shadowing.

Duke Scholars

Published In

Peptides

DOI

ISSN

0196-9781

Publication Date

1994

Volume

15

Issue

7

Start / End Page

1255 / 1259

Location

United States

Related Subject Headings

  • Reference Standards
  • Myocardium
  • Male
  • Dogs
  • Chromatography, High Pressure Liquid
  • Animals
  • Angiotensins
  • Angiotensin II
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Naik, G. O., Forster, C., & Armstrong, P. W. (1994). Measurement of angiotensin II: use of two injectors to minimize HPLC shadowing. Peptides, 15(7), 1255–1259. https://doi.org/10.1016/0196-9781(94)90150-3
Naik, G. O., C. Forster, and P. W. Armstrong. “Measurement of angiotensin II: use of two injectors to minimize HPLC shadowing.Peptides 15, no. 7 (1994): 1255–59. https://doi.org/10.1016/0196-9781(94)90150-3.
Naik GO, Forster C, Armstrong PW. Measurement of angiotensin II: use of two injectors to minimize HPLC shadowing. Peptides. 1994;15(7):1255–9.
Naik, G. O., et al. “Measurement of angiotensin II: use of two injectors to minimize HPLC shadowing.Peptides, vol. 15, no. 7, 1994, pp. 1255–59. Pubmed, doi:10.1016/0196-9781(94)90150-3.
Naik GO, Forster C, Armstrong PW. Measurement of angiotensin II: use of two injectors to minimize HPLC shadowing. Peptides. 1994;15(7):1255–1259.
Journal cover image

Published In

Peptides

DOI

ISSN

0196-9781

Publication Date

1994

Volume

15

Issue

7

Start / End Page

1255 / 1259

Location

United States

Related Subject Headings

  • Reference Standards
  • Myocardium
  • Male
  • Dogs
  • Chromatography, High Pressure Liquid
  • Animals
  • Angiotensins
  • Angiotensin II