Skip to main content
Journal cover image

Is Metal-On-Metal Total Hip Arthroplasty Associated With Neurotoxicity?

Publication ,  Journal Article
Bala, A; Penrose, CT; Seyler, TM; Randell, TR; Wellman, SS; Bolognesi, MP
Published in: J Arthroplasty
September 2016

BACKGROUND: Isolated case reports in the literature describe systemic neurologic side effects associated with metal-on-metal (MOM) bearing surfaces, yet the incidence of these effects have not been evaluated beyond individual cases. The purpose of this study was to compare new diagnoses of these side effects described in isolated cases in large patient cohorts of MOM vs metal on polyethylene (MOP). METHODS: We queried the entire Medicare database from 2005 to 2012. Total hip arthroplasty (THA) and bearing surface were determined using International Classification of Diseases, 9th revision procedure codes. Patients with 5-year follow-up were selected. Using International Classification of Diseases, 9th revision codes, we identified new diagnoses of previously reported neurologic side effects: peripheral neuropathy, sensorineural hearing loss, visual impairment, paresthesias, tinnitus, and vertigo. Comorbidities and demographics were collected. Odds ratios, CIs, and P values were calculated. RESULTS: Overall, 29,483 MOM THAs and 23,587 age- and gender-matched MOP THAs were identified. The average Charlson Comorbidity Index was 5 for both groups. MOM and MOP patients had 26 of 30 identical prevalence of Elixhauser-measure comorbidities. There was no statistically significant difference in new diagnoses of any of the side effects at any time point between the 2 groups over 5 years. CONCLUSION: This study represents, to our knowledge, the first longitudinal analysis of systemic neurotoxicity after THA in a large cohort of patients. The results of our study suggest that on the large scale, neurologic side effects previously described do not occur as a common attributable complication. Rather, these cases may be due to individual patient hypersensitivity to metal ions.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

J Arthroplasty

DOI

EISSN

1532-8406

Publication Date

September 2016

Volume

31

Issue

9 Suppl

Start / End Page

233 / 236.e1

Location

United States

Related Subject Headings

  • United States
  • Prosthesis Design
  • Polyethylene
  • Orthopedics
  • Neurotoxicity Syndromes
  • Middle Aged
  • Metals
  • Metal-on-Metal Joint Prostheses
  • Medicare
  • Male
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Bala, A., Penrose, C. T., Seyler, T. M., Randell, T. R., Wellman, S. S., & Bolognesi, M. P. (2016). Is Metal-On-Metal Total Hip Arthroplasty Associated With Neurotoxicity? J Arthroplasty, 31(9 Suppl), 233-236.e1. https://doi.org/10.1016/j.arth.2016.03.035
Bala, Abiram, Colin T. Penrose, Thorsten M. Seyler, Timmothy R. Randell, Samuel S. Wellman, and Michael P. Bolognesi. “Is Metal-On-Metal Total Hip Arthroplasty Associated With Neurotoxicity?J Arthroplasty 31, no. 9 Suppl (September 2016): 233-236.e1. https://doi.org/10.1016/j.arth.2016.03.035.
Bala A, Penrose CT, Seyler TM, Randell TR, Wellman SS, Bolognesi MP. Is Metal-On-Metal Total Hip Arthroplasty Associated With Neurotoxicity? J Arthroplasty. 2016 Sep;31(9 Suppl):233-236.e1.
Bala, Abiram, et al. “Is Metal-On-Metal Total Hip Arthroplasty Associated With Neurotoxicity?J Arthroplasty, vol. 31, no. 9 Suppl, Sept. 2016, pp. 233-236.e1. Pubmed, doi:10.1016/j.arth.2016.03.035.
Bala A, Penrose CT, Seyler TM, Randell TR, Wellman SS, Bolognesi MP. Is Metal-On-Metal Total Hip Arthroplasty Associated With Neurotoxicity? J Arthroplasty. 2016 Sep;31(9 Suppl):233-236.e1.
Journal cover image

Published In

J Arthroplasty

DOI

EISSN

1532-8406

Publication Date

September 2016

Volume

31

Issue

9 Suppl

Start / End Page

233 / 236.e1

Location

United States

Related Subject Headings

  • United States
  • Prosthesis Design
  • Polyethylene
  • Orthopedics
  • Neurotoxicity Syndromes
  • Middle Aged
  • Metals
  • Metal-on-Metal Joint Prostheses
  • Medicare
  • Male