Skip to main content

Performance and Validation of a Novel Biomarker-Based Stroke Risk Score for Atrial Fibrillation.

Publication ,  Journal Article
Oldgren, J; Hijazi, Z; Lindbäck, J; Alexander, JH; Connolly, SJ; Eikelboom, JW; Ezekowitz, MD; Granger, CB; Hylek, EM; Lopes, RD; Siegbahn, A ...
Published in: Circulation
November 29, 2016

BACKGROUND: Atrial fibrillation is associated with increased but variable risk of stroke. Our aim was to validate the recently developed biomarker-based ABC (age, biomarkers [high-sensitivity troponin and N-terminal fragment B-type natriuretic peptide], and clinical history of prior stroke/transient ischemic attack)-stroke risk score and compare its performance with the CHA2DS2VASc and ATRIA (Anticoagulation and Risk Factors in Atrial Fibrillation) risk scores. METHODS: The ABC-stroke score includes age, biomarkers (N-terminal fragment B-type natriuretic peptide and high-sensitivity cardiac troponin), and clinical history (prior stroke). This validation was based on 8356 patients, 16 137 person-years of follow-up, and 219 adjudicated stroke or systemic embolic events in anticoagulated patients with atrial fibrillation in the RE-LY study (Randomized Evaluation of Long-Term Anticoagulation Therapy). Levels of N-terminal fragment B-type natriuretic peptide, high-sensitivity cardiac troponin T (hs-cTnT), and high-sensitivity cardiac troponin I (hs-cTnI) were determined in plasma samples obtained at study entry. RESULTS: The ABC-stroke score was well calibrated with 0.76 stroke/systemic embolic events per 100 person-years in the predefined low (<1%/y) risk group, 1.48 in the medium (1%-2%/y) risk group, and 2.60 in the high (>2%/y) risk group for the ABC-stroke score with hs-cTnT. Hazard ratios for stroke/systemic embolic events were 1.95 for medium- versus low-risk groups, and 3.44 for high- versus low-risk groups. ABC-stroke score achieved C indices of 0.65 with both hs-cTnT and hs-cTnI, in comparison with 0.60 for CHA2DS2VASc (P=0.004 for hs-cTnT and P=0.022 hs-cTnI) and 0.61 for ATRIA scores (P=0.005 hs-cTnT and P=0.034 for hs-cTnI). CONCLUSIONS: The biomarker-based ABC-stroke score was well calibrated and consistently performed better than both the CHA2DS2VASc and ATRIA stroke scores. The ABC score should be considered an improved decision support tool in the care of patients with atrial fibrillation. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifiers: ARISTOTLE, NCT00412984; RE-LY, NCT00262600.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Circulation

DOI

EISSN

1524-4539

Publication Date

November 29, 2016

Volume

134

Issue

22

Start / End Page

1697 / 1707

Location

United States

Related Subject Headings

  • Young Adult
  • Troponin
  • Stroke
  • Severity of Illness Index
  • Reproducibility of Results
  • Peptide Fragments
  • Natriuretic Peptide, Brain
  • Middle Aged
  • Male
  • Humans
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Oldgren, J., Hijazi, Z., Lindbäck, J., Alexander, J. H., Connolly, S. J., Eikelboom, J. W., … RE-LY and ARISTOTLE Investigators, . (2016). Performance and Validation of a Novel Biomarker-Based Stroke Risk Score for Atrial Fibrillation. Circulation, 134(22), 1697–1707. https://doi.org/10.1161/CIRCULATIONAHA.116.022802
Oldgren, Jonas, Ziad Hijazi, Johan Lindbäck, John H. Alexander, Stuart J. Connolly, John W. Eikelboom, Michael D. Ezekowitz, et al. “Performance and Validation of a Novel Biomarker-Based Stroke Risk Score for Atrial Fibrillation.Circulation 134, no. 22 (November 29, 2016): 1697–1707. https://doi.org/10.1161/CIRCULATIONAHA.116.022802.
Oldgren J, Hijazi Z, Lindbäck J, Alexander JH, Connolly SJ, Eikelboom JW, et al. Performance and Validation of a Novel Biomarker-Based Stroke Risk Score for Atrial Fibrillation. Circulation. 2016 Nov 29;134(22):1697–707.
Oldgren, Jonas, et al. “Performance and Validation of a Novel Biomarker-Based Stroke Risk Score for Atrial Fibrillation.Circulation, vol. 134, no. 22, Nov. 2016, pp. 1697–707. Pubmed, doi:10.1161/CIRCULATIONAHA.116.022802.
Oldgren J, Hijazi Z, Lindbäck J, Alexander JH, Connolly SJ, Eikelboom JW, Ezekowitz MD, Granger CB, Hylek EM, Lopes RD, Siegbahn A, Yusuf S, Wallentin L, RE-LY and ARISTOTLE Investigators. Performance and Validation of a Novel Biomarker-Based Stroke Risk Score for Atrial Fibrillation. Circulation. 2016 Nov 29;134(22):1697–1707.

Published In

Circulation

DOI

EISSN

1524-4539

Publication Date

November 29, 2016

Volume

134

Issue

22

Start / End Page

1697 / 1707

Location

United States

Related Subject Headings

  • Young Adult
  • Troponin
  • Stroke
  • Severity of Illness Index
  • Reproducibility of Results
  • Peptide Fragments
  • Natriuretic Peptide, Brain
  • Middle Aged
  • Male
  • Humans