Skip to main content
Journal cover image

How to Optimally Apply Impedance in the Evaluation of Esophageal Dysmotility.

Publication ,  Journal Article
Patel, A; Gyawali, CP
Published in: Curr Gastroenterol Rep
November 2016

The utilization of impedance technology has enhanced our understanding and assessment of esophageal dysmotility. Esophageal high-resolution manometry (HRM) catheters incorporated with multiple impedance electrodes help assess esophageal bolus transit, and the combination is termed high-resolution impedance manometry (HRIM). Novel metrics have been developed with HRIM-including esophageal impedance integral ratio, bolus flow time, nadir impedance pressure, and impedance bolus height-that augments the assessment of esophageal bolus transit. Automated impedance-manometry (AIM) analysis has enhanced understanding of the relationship between bolus transit and pressure phenomena. Impedance-based metrics have improved understanding of the dynamics of esophageal bolus transit into four distinct phases, may correlate with symptomatic burden, and can assess the adequacy of therapy for achalasia. An extension of the use of impedance involves impedance planimetry and the functional lumen imaging probe (FLIP), which assesses esophageal biophysical properties and distensibility, and could detect patterns of esophageal contractility not seen on HRM. Impedance technology, therefore, has a significant impact on esophageal function testing in the present day.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Curr Gastroenterol Rep

DOI

EISSN

1534-312X

Publication Date

November 2016

Volume

18

Issue

11

Start / End Page

60

Location

United States

Related Subject Headings

  • Manometry
  • Humans
  • Gastrointestinal Transit
  • Gastroesophageal Reflux
  • Gastroenterology & Hepatology
  • Esophagus
  • Esophageal Motility Disorders
  • Esophageal Achalasia
  • Electric Impedance
  • 3202 Clinical sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Patel, A., & Gyawali, C. P. (2016). How to Optimally Apply Impedance in the Evaluation of Esophageal Dysmotility. Curr Gastroenterol Rep, 18(11), 60. https://doi.org/10.1007/s11894-016-0534-9
Patel, Amit, and C Prakash Gyawali. “How to Optimally Apply Impedance in the Evaluation of Esophageal Dysmotility.Curr Gastroenterol Rep 18, no. 11 (November 2016): 60. https://doi.org/10.1007/s11894-016-0534-9.
Patel A, Gyawali CP. How to Optimally Apply Impedance in the Evaluation of Esophageal Dysmotility. Curr Gastroenterol Rep. 2016 Nov;18(11):60.
Patel, Amit, and C. Prakash Gyawali. “How to Optimally Apply Impedance in the Evaluation of Esophageal Dysmotility.Curr Gastroenterol Rep, vol. 18, no. 11, Nov. 2016, p. 60. Pubmed, doi:10.1007/s11894-016-0534-9.
Patel A, Gyawali CP. How to Optimally Apply Impedance in the Evaluation of Esophageal Dysmotility. Curr Gastroenterol Rep. 2016 Nov;18(11):60.
Journal cover image

Published In

Curr Gastroenterol Rep

DOI

EISSN

1534-312X

Publication Date

November 2016

Volume

18

Issue

11

Start / End Page

60

Location

United States

Related Subject Headings

  • Manometry
  • Humans
  • Gastrointestinal Transit
  • Gastroesophageal Reflux
  • Gastroenterology & Hepatology
  • Esophagus
  • Esophageal Motility Disorders
  • Esophageal Achalasia
  • Electric Impedance
  • 3202 Clinical sciences