PURPOSE: To compare the measurement of the central corneal thickness (CCT) by Visante (Carl Zeiss Meditec, Dublin, California, USA) anterior segment optical coherence tomography (AS-OCT) with ultrasound pachymetry. DESIGN: Population-based, cross-sectional study. METHODS: Participants were part of a population-based study of 3280 Malay subjects aged 40 to 80 years in Singapore. Ultrasound pachmetry of CCT was performed on all participants and approximately 10% underwent further evaluation with AS-OCT. RESULTS: Two hundred and eighty-five consecutive subjects were included, with a mean age of 57.9 (+/- 10.8) years. CCT as measured by ultrasound pachymetry was highly correlated with the equivalent AS-OCT reading (The Pearson correlation coefficient = 0.93, P < .001). However, Bland-Altman analysis showed that CCT as measured by ultrasound pachymetry was significantly higher by 16.5 +/- 11.7 microm (limits of agreement -6.1 to 39.1, P < .001). CONCLUSIONS: CCT measured by Visante AS-OCT was highly correlated with that from ultrasound pachymetry. However, CCT readings by Visante AS-OCT were consistently less than that of ultrasound pachymetry.

Duke Scholars

Published In

Am J Ophthalmol

DOI

ISSN

0002-9394

Publication Date

June 2007

Volume

143

Issue

6

Start / End Page

1047 / 1049

Location

United States

Related Subject Headings

  • Ultrasonography
  • Tomography, Optical Coherence
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Ophthalmology & Optometry
  • Middle Aged
  • Male
  • Humans
  • Female
  • Diagnostic Techniques, Ophthalmological
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Zhao, P. S., Wong, T. Y., Wong, W.-L., Saw, S.-M., & Aung, T. (2007). Comparison of central corneal thickness measurements by visante anterior segment optical coherence tomography with ultrasound pachymetry. Am J Ophthalmol, 143(6), 1047–1049. https://doi.org/10.1016/j.ajo.2007.01.050
Zhao, Paul S., Tien Yin Wong, Wan-Ling Wong, Seang-Mei Saw, and Tin Aung. “Comparison of central corneal thickness measurements by visante anterior segment optical coherence tomography with ultrasound pachymetry.Am J Ophthalmol 143, no. 6 (June 2007): 1047–49. https://doi.org/10.1016/j.ajo.2007.01.050.
Zhao, Paul S., et al. “Comparison of central corneal thickness measurements by visante anterior segment optical coherence tomography with ultrasound pachymetry.Am J Ophthalmol, vol. 143, no. 6, June 2007, pp. 1047–49. Pubmed, doi:10.1016/j.ajo.2007.01.050.
Journal cover image

Published In

Am J Ophthalmol

DOI

ISSN

0002-9394

Publication Date

June 2007

Volume

143

Issue

6

Start / End Page

1047 / 1049

Location

United States

Related Subject Headings

  • Ultrasonography
  • Tomography, Optical Coherence
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Ophthalmology & Optometry
  • Middle Aged
  • Male
  • Humans
  • Female
  • Diagnostic Techniques, Ophthalmological