Skip to main content
construction release_alert
Scholars@Duke will be undergoing maintenance April 11-15. Some features may be unavailable during this time.
cancel

A computer assisted method for nuclear cataract grading from slit-lamp images using ranking.

Publication ,  Journal Article
Huang, W; Chan, KL; Li, H; Lim, JH; Liu, J; Wong, TY
Published in: IEEE Trans Med Imaging
January 2011

In clinical diagnosis, a grade indicating the severity of nuclear cataract is often manually assigned by a trained ophthalmologist to a patient after comparing the lens' opacity severity in his/her slit-lamp images with a set of standard photos. This grading scheme is often subjective and time-consuming. In this paper, a novel computer-aided diagnosis method via ranking is proposed to facilitate nuclear cataract grading following conventional clinical decision-making process. The grade of nuclear cataract in a slit-lamp image is predicted using its neighboring labeled images in a ranked image list, which is achieved using a learned ranking function. This ranking function is learned via direct optimization on a newly proposed approximation to a ranking evaluation measure. Our proposed method has been evaluated by a large dataset composed of 1000 different cases, which are collected from an ongoing clinical population-based study. Both experimental results and comparison with several existing methods demonstrate the benefit of grading via ranking by our proposed method.

Duke Scholars

Published In

IEEE Trans Med Imaging

DOI

EISSN

1558-254X

Publication Date

January 2011

Volume

30

Issue

1

Start / End Page

94 / 107

Location

United States

Related Subject Headings

  • Statistics, Nonparametric
  • Research Design
  • Physical Examination
  • Photography
  • Nuclear Medicine & Medical Imaging
  • Lens Nucleus, Crystalline
  • Humans
  • Diagnostic Techniques, Ophthalmological
  • Diagnostic Imaging
  • Diagnosis, Computer-Assisted
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Huang, W., Chan, K. L., Li, H., Lim, J. H., Liu, J., & Wong, T. Y. (2011). A computer assisted method for nuclear cataract grading from slit-lamp images using ranking. IEEE Trans Med Imaging, 30(1), 94–107. https://doi.org/10.1109/TMI.2010.2062197
Huang, Wei, Kap Luk Chan, Huiqi Li, Joo Hwee Lim, Jiang Liu, and Tien Yin Wong. “A computer assisted method for nuclear cataract grading from slit-lamp images using ranking.IEEE Trans Med Imaging 30, no. 1 (January 2011): 94–107. https://doi.org/10.1109/TMI.2010.2062197.
Huang W, Chan KL, Li H, Lim JH, Liu J, Wong TY. A computer assisted method for nuclear cataract grading from slit-lamp images using ranking. IEEE Trans Med Imaging. 2011 Jan;30(1):94–107.
Huang, Wei, et al. “A computer assisted method for nuclear cataract grading from slit-lamp images using ranking.IEEE Trans Med Imaging, vol. 30, no. 1, Jan. 2011, pp. 94–107. Pubmed, doi:10.1109/TMI.2010.2062197.
Huang W, Chan KL, Li H, Lim JH, Liu J, Wong TY. A computer assisted method for nuclear cataract grading from slit-lamp images using ranking. IEEE Trans Med Imaging. 2011 Jan;30(1):94–107.

Published In

IEEE Trans Med Imaging

DOI

EISSN

1558-254X

Publication Date

January 2011

Volume

30

Issue

1

Start / End Page

94 / 107

Location

United States

Related Subject Headings

  • Statistics, Nonparametric
  • Research Design
  • Physical Examination
  • Photography
  • Nuclear Medicine & Medical Imaging
  • Lens Nucleus, Crystalline
  • Humans
  • Diagnostic Techniques, Ophthalmological
  • Diagnostic Imaging
  • Diagnosis, Computer-Assisted