Skip to main content

Inter-rater reliability of ultrasound imaging of the trunk musculature among novice raters.

Publication ,  Journal Article
Teyhen, DS; George, SZ; Dugan, JL; Williamson, J; Neilson, BD; Childs, JD
Published in: J Ultrasound Med
March 2011

OBJECTIVE: The purpose of this study was to determine the inter-rater reliability of ultrasound imaging for assessing trunk muscle morphologic characteristics at rest and while contracted among different pairs of novice raters. The secondary purpose was to compare 3 different measurement techniques for assessing lateral abdominal muscle thickness. METHODS: A single-group repeated measures reliability study was conducted on 21 healthy participants (mean ± SD, 21.5 ± 4.4 years; 5 female and 16 male) without low back pain. Ultrasound images of the transversus abdominis, internal oblique, rectus abdominis, and lumbar multifidus muscles were obtained by different pairs of novice raters in a counterbalanced order. All raters received a standardized training program before obtaining measurements. RESULTS: The intraclass correlation coefficient (1, 3) point estimates ranged from 0.86 to 0.94; the standard error of the measurement ranged from 0.04 to 0.16 cm for the thickness values and 0.67 cm(2) for the cross-sectional area of the rectus abdominis muscle. There was no meaningful difference between the different measurement techniques used to analyze the lateral abdominal muscles. CONCLUSIONS: Good to excellent reliability was obtained for all measures by novice raters. Minimal differences in reliability were noted between the different measurement techniques to assess lateral abdominal muscle thickness.

Duke Scholars

Published In

J Ultrasound Med

DOI

EISSN

1550-9613

Publication Date

March 2011

Volume

30

Issue

3

Start / End Page

347 / 356

Location

England

Related Subject Headings

  • Young Adult
  • Ultrasonography
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Reference Values
  • Observer Variation
  • Nuclear Medicine & Medical Imaging
  • Military Personnel
  • Male
  • Humans
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Teyhen, D. S., George, S. Z., Dugan, J. L., Williamson, J., Neilson, B. D., & Childs, J. D. (2011). Inter-rater reliability of ultrasound imaging of the trunk musculature among novice raters. J Ultrasound Med, 30(3), 347–356. https://doi.org/10.7863/jum.2011.30.3.347
Teyhen, Deydre S., Steven Z. George, Jessica L. Dugan, Jared Williamson, Brett D. Neilson, and John D. Childs. “Inter-rater reliability of ultrasound imaging of the trunk musculature among novice raters.J Ultrasound Med 30, no. 3 (March 2011): 347–56. https://doi.org/10.7863/jum.2011.30.3.347.
Teyhen DS, George SZ, Dugan JL, Williamson J, Neilson BD, Childs JD. Inter-rater reliability of ultrasound imaging of the trunk musculature among novice raters. J Ultrasound Med. 2011 Mar;30(3):347–56.
Teyhen, Deydre S., et al. “Inter-rater reliability of ultrasound imaging of the trunk musculature among novice raters.J Ultrasound Med, vol. 30, no. 3, Mar. 2011, pp. 347–56. Pubmed, doi:10.7863/jum.2011.30.3.347.
Teyhen DS, George SZ, Dugan JL, Williamson J, Neilson BD, Childs JD. Inter-rater reliability of ultrasound imaging of the trunk musculature among novice raters. J Ultrasound Med. 2011 Mar;30(3):347–356.

Published In

J Ultrasound Med

DOI

EISSN

1550-9613

Publication Date

March 2011

Volume

30

Issue

3

Start / End Page

347 / 356

Location

England

Related Subject Headings

  • Young Adult
  • Ultrasonography
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Reference Values
  • Observer Variation
  • Nuclear Medicine & Medical Imaging
  • Military Personnel
  • Male
  • Humans