TH-C-19A-05: Evaluation of a New Reusable 3D Dosimeter.

Publication ,  Journal Article
Juang, T; Adamovics, J; Oldham, M
Published in: Med Phys
June 2014

PURPOSE: PRESAGE is a radiochromic plastic which has demonstrated strong potential for high resolution single-use 3D dosimetry. This study evaluates a new PRESAGE formulation (Presage-RU) in which the radiochromic response is reversible (the dosimeter optically clears after irradiation), enabling the potential for reusability. METHODS: Presage-RU dose response and optical-clearing rates were evaluated in both small volume dosimeters (1×1×4.5cm) and a larger cylindrical dosimeter (8cm diameter, 4.5cm length). All dosimeters were allowed to fully optically clear in dark, room temperature conditions between irradiations. Dose response was determined by irradiating small volume samples from 0-8.0Gy and measuring change in optical density. The cylindrical dosimeter was irradiated with a simple 4-field box plan (parallel opposed pairs of 4cm×4cm AP-PA beams and 2cm×4cm lateral beams) to 20Gy. High resolution 3D dosimetry was achieved utilizing optical-CT readout. Readings were tracked up to 14 days to characterize optical clearing. RESULTS: Initial irradiation yielded a response of 0.0119△OD/(Gy*cm) while two subsequent reirradiations yielded a lower but consistent response of 0.0087△OD/(Gy*cm). Strong linearity of dose response was observed for all irradiations. In the large cylindrical dosimeter, the integral dose within the high dose region exhibited an exponential decay in signal over time (halflife= 23.9 hours), with the dosimeter effectively cleared (0.04% of the initial signal) after 10 days. Subsequent irradiation resulted in 19.5% lower initial signal but demonstrated that the exponential clearing rate remained consistent. Results of additional subsequent irradiations will also be presented. CONCLUSION: This work introduces a new re-usable radiochromic dosimeter (Presage-RU) compatible with high resolution (sub-millimeter) 3D dosimetry. Sensitivity of the initial radiation was observed to be slightly higher than subsequent irradiations, but the clearing time remained constant, indicating the dosimeter can be re-used after 10 days. Presage-RU has potential to dramatically improve cost-effectiveness and thereby lower the barrier for implementing comprehensive, high resolution 3D dosimetry. John Adamovics is the president of Heuris Inc., which commercializes PRESAGE.

Duke Scholars

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

June 2014

Volume

41

Issue

6

Start / End Page

548

Location

United States

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Juang, T., Adamovics, J., & Oldham, M. (2014). TH-C-19A-05: Evaluation of a New Reusable 3D Dosimeter. Med Phys, 41(6), 548. https://doi.org/10.1118/1.4889590
Juang, T., J. Adamovics, and M. Oldham. “TH-C-19A-05: Evaluation of a New Reusable 3D Dosimeter.Med Phys 41, no. 6 (June 2014): 548. https://doi.org/10.1118/1.4889590.
Juang T, Adamovics J, Oldham M. TH-C-19A-05: Evaluation of a New Reusable 3D Dosimeter. Med Phys. 2014 Jun;41(6):548.
Juang, T., et al. “TH-C-19A-05: Evaluation of a New Reusable 3D Dosimeter.Med Phys, vol. 41, no. 6, June 2014, p. 548. Pubmed, doi:10.1118/1.4889590.
Juang T, Adamovics J, Oldham M. TH-C-19A-05: Evaluation of a New Reusable 3D Dosimeter. Med Phys. 2014 Jun;41(6):548.

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

June 2014

Volume

41

Issue

6

Start / End Page

548

Location

United States

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences