SU-E-I-56: Scan Angle Reduction for a Limited-Angle Intrafraction Verification (LIVE) System.

Publication ,  Conference
Ren, L; Zhang, Y; Yin, F
Published in: Med Phys
June 2014

PURPOSE: To develop a novel adaptive reconstruction strategy to further reduce the scanning angle required by the limited-angle intrafraction verification (LIVE) system for intrafraction verification. METHODS: LIVE acquires limited angle MV projections from the exit fluence of the arc treatment beam or during gantry rotation between static beams. Orthogonal limited-angle kV projections are also acquired simultaneously to provide additional information. LIVE considers the on-board 4D-CBCT images as a deformation of the prior 4D-CT images, and solves the deformation field based on deformation models and data fidelity constraint. LIVE reaches a checkpoint after a limited-angle scan, and reconstructs 4D-CBCT for intrafraction verification at the checkpoint. In adaptive reconstruction strategy, a larger scanning angle of 30° is used for the first checkpoint, and smaller scanning angles of 15° are used for subsequent checkpoints. The onboard images reconstructed at the previous adjacent checkpoint are used as the prior images for reconstruction at the current checkpoint. As the algorithm only needs to reconstruct the small deformation occurred between adjacent checkpoints, projections from a smaller scan angle provide enough information for the reconstruction. XCAT was used to simulate tumor motion baseline drift of 2mm along sup-inf direction at every subsequent checkpoint, which are 15° apart. Adaptive reconstruction strategy was used to reconstruct the images at each checkpoint using orthogonal 15° kV and MV projections. RESULTS: Results showed that LIVE reconstructed the tumor volumes accurately using orthogonal 15° kV-MV projections. Volume percentage differences (VPDs) were within 5% and center of mass shifts (COMS) were within 1mm for reconstruction at all checkpoints. CONCLUSION: It's feasible to use an adaptive reconstruction strategy to further reduce the scan angle needed by LIVE to allow faster and more frequent intrafraction verification to minimize the treatment errors in lung cancer treatments. Grant from Varian Medical System.

Duke Scholars

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

June 2014

Volume

41

Issue

6

Start / End Page

143

Location

United States

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Ren, L., Zhang, Y., & Yin, F. (2014). SU-E-I-56: Scan Angle Reduction for a Limited-Angle Intrafraction Verification (LIVE) System. In Med Phys (Vol. 41, p. 143). United States. https://doi.org/10.1118/1.4888006
Ren, L., Y. Zhang, and F. Yin. “SU-E-I-56: Scan Angle Reduction for a Limited-Angle Intrafraction Verification (LIVE) System.” In Med Phys, 41:143, 2014. https://doi.org/10.1118/1.4888006.
Ren, L., et al. “SU-E-I-56: Scan Angle Reduction for a Limited-Angle Intrafraction Verification (LIVE) System.Med Phys, vol. 41, no. 6, 2014, p. 143. Pubmed, doi:10.1118/1.4888006.

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

June 2014

Volume

41

Issue

6

Start / End Page

143

Location

United States

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences