TH-AB-207A-01: Contrast-Enhanced CT: Correlation of Radiation Dose and Biological Effect.

Publication ,  Journal Article
Abadi, E; Sanders, J; Agasthya, G; Segars, P; Samei, E
Published in: Med Phys
June 2016

PURPOSE: The potential risk from CT is generally characterized in terms of radiation dose. The presence of iodinated-contrast medium increases radiation dose. However, it is unclear how much of this increase is biologically relevant. The purpose of this study was to establish the contribution of dose increase from iodine to biological effect. METHODS: Radiation organ dose was estimated in 58 human (XCAT) phantoms "undergoing" chest CT examination (120 kVp, 9 mGy CTDI) on a simulated CT system (Definition Flash, Siemens) with and without iodinated-contrast agent (62.5 mL of iodine per subject). The dose without and with the presence of iodine was compared to the increase in foci per cell (a surrogate of DNA damage) measured before and after similar CT exams without and with contrast agent (Piechowiak et al. 2015). The data were analyzed to ascertain how the enhancement in biological effect in contrast-enhanced CTs correlated with the increase in dose due to the presence of iodine. RESULTS: The presence of iodinated-contrast in CT increased the organ doses by 2% to 50% on average. Typical values were heart (50%±7%), kidney (19%±7%), and liver (2%±3%). The corresponding increase in the average foci per cell was 107%±19%, indicating biological effect of iodine was greater than what would be anticipated from the iodine-initiated increase in radiation dose alone. CONCLUSION: Mean foci per cell and organ dose both increase in the presence of contrast agent. The former, however, is at least twice as large as the latter, indicating that iodine contributes to an increase in the probability of DNA damage not only as a consequence of increased x-ray energy deposition but also from other mechanisms. Hence iodine radiation dose, while relevant to be included in estimating the risk associated with contrast-enhanced CT, still can underestimate the biological effects.

Duke Scholars

Published In

Med Phys

DOI

EISSN

2473-4209

Publication Date

June 2016

Volume

43

Issue

6

Start / End Page

3859

Location

United States

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Abadi, E., Sanders, J., Agasthya, G., Segars, P., & Samei, E. (2016). TH-AB-207A-01: Contrast-Enhanced CT: Correlation of Radiation Dose and Biological Effect. Med Phys, 43(6), 3859. https://doi.org/10.1118/1.4958077
Abadi, E., J. Sanders, G. Agasthya, P. Segars, and E. Samei. “TH-AB-207A-01: Contrast-Enhanced CT: Correlation of Radiation Dose and Biological Effect.Med Phys 43, no. 6 (June 2016): 3859. https://doi.org/10.1118/1.4958077.
Abadi E, Sanders J, Agasthya G, Segars P, Samei E. TH-AB-207A-01: Contrast-Enhanced CT: Correlation of Radiation Dose and Biological Effect. Med Phys. 2016 Jun;43(6):3859.
Abadi, E., et al. “TH-AB-207A-01: Contrast-Enhanced CT: Correlation of Radiation Dose and Biological Effect.Med Phys, vol. 43, no. 6, June 2016, p. 3859. Pubmed, doi:10.1118/1.4958077.
Abadi E, Sanders J, Agasthya G, Segars P, Samei E. TH-AB-207A-01: Contrast-Enhanced CT: Correlation of Radiation Dose and Biological Effect. Med Phys. 2016 Jun;43(6):3859.

Published In

Med Phys

DOI

EISSN

2473-4209

Publication Date

June 2016

Volume

43

Issue

6

Start / End Page

3859

Location

United States

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences