Skip to main content
Journal cover image

A method to measure arbitrary k-space trajectories for rapid MR imaging.

Publication ,  Journal Article
Mason, GF; Harshbarger, T; Hetherington, HP; Zhang, Y; Pohost, GM; Twieg, DB
Published in: Magn Reson Med
September 1997

A method to measure arbitrary k-space trajectories was developed to compensate for nonideal gradient performance during rapid magnetic resonance (MR) imaging with actively or nonactively shielded gradients at a magnetic field strength of 4.1 T. Accurate MR image reconstruction requires knowledge of the k-trajectory produced by the gradient waveforms during k-space sampling. Even with shielded gradients, residual eddy currents and imperfections in gradient amplifier performance can cause the true k-space trajectory to deviate from the ideal trajectory. The k-space determination was used for spiral gradient-echo imaging fo the human brain. While individual calibrations are needed for new pulse sequences, the method of k-space determination can be used for any sequence of preparation pulses and readout gradient waveforms and should prove useful for other trajectories, including the rastered lines of echo-planar imaging.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Magn Reson Med

DOI

ISSN

0740-3194

Publication Date

September 1997

Volume

38

Issue

3

Start / End Page

492 / 496

Location

United States

Related Subject Headings

  • Reproducibility of Results
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Imaging
  • Image Processing, Computer-Assisted
  • Humans
  • Brain
  • Artifacts
  • 4003 Biomedical engineering
  • 0903 Biomedical Engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Mason, G. F., Harshbarger, T., Hetherington, H. P., Zhang, Y., Pohost, G. M., & Twieg, D. B. (1997). A method to measure arbitrary k-space trajectories for rapid MR imaging. Magn Reson Med, 38(3), 492–496. https://doi.org/10.1002/mrm.1910380318
Mason, G. F., T. Harshbarger, H. P. Hetherington, Y. Zhang, G. M. Pohost, and D. B. Twieg. “A method to measure arbitrary k-space trajectories for rapid MR imaging.Magn Reson Med 38, no. 3 (September 1997): 492–96. https://doi.org/10.1002/mrm.1910380318.
Mason GF, Harshbarger T, Hetherington HP, Zhang Y, Pohost GM, Twieg DB. A method to measure arbitrary k-space trajectories for rapid MR imaging. Magn Reson Med. 1997 Sep;38(3):492–6.
Mason, G. F., et al. “A method to measure arbitrary k-space trajectories for rapid MR imaging.Magn Reson Med, vol. 38, no. 3, Sept. 1997, pp. 492–96. Pubmed, doi:10.1002/mrm.1910380318.
Mason GF, Harshbarger T, Hetherington HP, Zhang Y, Pohost GM, Twieg DB. A method to measure arbitrary k-space trajectories for rapid MR imaging. Magn Reson Med. 1997 Sep;38(3):492–496.
Journal cover image

Published In

Magn Reson Med

DOI

ISSN

0740-3194

Publication Date

September 1997

Volume

38

Issue

3

Start / End Page

492 / 496

Location

United States

Related Subject Headings

  • Reproducibility of Results
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Imaging
  • Image Processing, Computer-Assisted
  • Humans
  • Brain
  • Artifacts
  • 4003 Biomedical engineering
  • 0903 Biomedical Engineering