Skip to main content
Journal cover image

Late loosening of press-fit cementless acetabular components.

Publication ,  Journal Article
Jiranek, WA; Whiddon, DR; Johnstone, WT
Published in: Clin Orthop Relat Res
January 2004

Between January 1987 and September 1990, 67 consecutive cementless total hip arthroplasties were implanted in 59 patients by one surgeon. The mean age of the patients at surgery was 57 years (range, 23-80 years). All acetabular components were plasma-sprayed titanium hemispheric cups with four peripheral rim fins, but additional screw fixation was not used. The mean followup was 10.4 years (range, 8.8-12.5 years). With revision as the endpoint, the failure rate of this acetabular component at a mean of 10.4 years was 28% (19/67). Of the 56 patients (56 hips) with radiographic followup, loosening of the acetabular shell occurred in 10 hips in 10 patients (18%). Seventy percent of these loosened cups failed by tilt which occurred in a rapid manner; all of the patients required revision surgery. We examined the manner of loosening of a press-fit acetabular component after early (5-year) results showed high hip scores and a low failure rate.

Duke Scholars

Published In

Clin Orthop Relat Res

DOI

ISSN

0009-921X

Publication Date

January 2004

Issue

418

Start / End Page

172 / 178

Location

United States

Related Subject Headings

  • Time Factors
  • Prosthesis Failure
  • Prosthesis Design
  • Orthopedics
  • Middle Aged
  • Male
  • Humans
  • Hip Prosthesis
  • Follow-Up Studies
  • Female
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Jiranek, W. A., Whiddon, D. R., & Johnstone, W. T. (2004). Late loosening of press-fit cementless acetabular components. Clin Orthop Relat Res, (418), 172–178. https://doi.org/10.1097/00003086-200401000-00028
Jiranek, W. A., D. R. Whiddon, and W. T. Johnstone. “Late loosening of press-fit cementless acetabular components.Clin Orthop Relat Res, no. 418 (January 2004): 172–78. https://doi.org/10.1097/00003086-200401000-00028.
Jiranek WA, Whiddon DR, Johnstone WT. Late loosening of press-fit cementless acetabular components. Clin Orthop Relat Res. 2004 Jan;(418):172–8.
Jiranek, W. A., et al. “Late loosening of press-fit cementless acetabular components.Clin Orthop Relat Res, no. 418, Jan. 2004, pp. 172–78. Pubmed, doi:10.1097/00003086-200401000-00028.
Jiranek WA, Whiddon DR, Johnstone WT. Late loosening of press-fit cementless acetabular components. Clin Orthop Relat Res. 2004 Jan;(418):172–178.
Journal cover image

Published In

Clin Orthop Relat Res

DOI

ISSN

0009-921X

Publication Date

January 2004

Issue

418

Start / End Page

172 / 178

Location

United States

Related Subject Headings

  • Time Factors
  • Prosthesis Failure
  • Prosthesis Design
  • Orthopedics
  • Middle Aged
  • Male
  • Humans
  • Hip Prosthesis
  • Follow-Up Studies
  • Female