Skip to main content

SU-E-T-645: Treatment of Multiple Brain Metastases Using Stereotactic Radiosurgery with Single-Isocenter Volumetric Modulated Arc Therapy: Comparison with Conventional Dynamic Conformal Arc and Static Beam Stereotactic Radiosurgery.

Publication ,  Conference
Huang, C; Ren, L; Kirkpatrick, J; Wang, Z
Published in: Med Phys
June 2012

PURPOSE: To investigate the treatment of multiple brain metastases using stereotactic radiosurgery with single-isocenter volumetric modulated arc therapy (VMAT) compared with conventional multi-isocenter dynamic conformal arc therapy (DCAT) and three-dimensional conformal radiation therapy (3D-CRT). METHODS: Seventeen patients with 2 to 5 brain metastatic lesions were studied. The number of patients with 5, 4, 3, and 2 lesions were 4, 5, 4, and 4, respectively. For patients treated with DCAT/3D-CRT plans, VMAT plans were retrospectively generated, and vice versa. Single-isocenter set up was employed in VMAT plans while the number of isocenters was proportional to the number of lesions in DCAT/3D-CRT plans. The DCAT/3D-CRT and VMAT plans were generated using iPlan® RT Dose Version 4.1.1 (BrainLAB, Germany) and Eclipse™ Version 8.6 (Varian, USA) treatment planning system, respectively. All plans were designed to be delivered on Novalis Tx™ system (Varian, USA and BrainLAB, Germany), in which the accelerator equipped with a high definition multileaf collimator (HDMLC). RESULTS: Conformity index for VMAT plans were equivalent to or better than that for DCAT/3D-CRT plans. While VMAT and DCAT/3D-CRT plans were similar in target coverage, quality of coverage for VMAT plans was better. However, the volume receiving 5Gy was 46% larger for VMAT plans. In addition, the distance from individual lesion to the VMAT isocenter has no impact on VMAT plans. Compared with DCAT/3D-CRT plans, the mean monitor units (MU) decreased by 42% and the estimated treatment time decreased by 49% for VMAT plans. CONCLUSIONS: This work suggests that single-isocenter VMAT is promising for stereotactic radiosurgery in the treatment of multiple brain metastases. Single-isocenter VMAT is able to achieve comparable conformity, target coverage and quality of coverage with significantly superior delivery efficiency.

Duke Scholars

Published In

Med Phys

DOI

EISSN

2473-4209

Publication Date

June 2012

Volume

39

Issue

6Part20

Start / End Page

3854

Location

United States

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM

Published In

Med Phys

DOI

EISSN

2473-4209

Publication Date

June 2012

Volume

39

Issue

6Part20

Start / End Page

3854

Location

United States

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences