SU‐C‐214‐06: Noise Power Properties of a Dual‐Detector Cone‐Beam CT System

Publication ,  Conference
li, H; Giles, W; Roper, J; Bowsher, J; Yin, F
Published in: Medical Physics
January 1, 2011

Purpose: Very little information is available for noise properties using a dual‐detector cone‐beam CT (CBCT) system. Geometric misalignment, cross‐scatter, and inhomogeneous detector response are additional concerns in a dual‐detector system. This study characterizes the noise power spectrum of a dual CBCT system for image‐guided radiation therapy (IGRT). Methods: A bench‐top dual‐detector CBCT system with two orthogonal 40×30cm flat panels has been developed in our laboratory. The noise power spectrum (NPS) was evaluated by scanning two uniform phantoms with diameters of around 26cm and 20cm under different kVs, mAs, and acquisition modes. The three‐dimensional NPS was calculated using 3D Fourier transform for a region of interest of 10×10×10cm3 as the metric to evaluate the noise performance. The structural fluctuations were removed by subtraction between two identical scans. The radial averaging is then calculated every degree in the central slice of the 3D Fourier space to reduce the measurement fluctuation. The profile of the radial averaging is used for comparison between dual/single detectors, at different kVs, mAs, and acquisition modes. Results: The NPS amplitude of the dual CBCT system can be up to 50% lower than that of a single CBCT system in simultaneous acquisition mode. In alternating acquisition mode, the NPS of the dual CBCT system is comparable both in amplitude and shape with a single CBCT system. The cross‐scatter is identified as the major contributing factor for the discrepancy. The cross‐scatter and the amplitude of the discrepancy are correlated with the sizes of the scanned objects under various current and voltage parameters. Conclusions: The Cross scatter reduces the amplitude of NPS. The effect is more dominant for large objects. Quantitative results from this noise power analysis provide guidance for dual CBCT reconstruction, cross‐scatter reduction and acquisition optimization. This work is supported in part by a research grant from Varian Medical Systems. © 2011, American Association of Physicists in Medicine. All rights reserved.

Duke Scholars

Published In

Medical Physics

DOI

ISSN

0094-2405

Publication Date

January 1, 2011

Volume

38

Issue

6

Start / End Page

3373

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
li, H., Giles, W., Roper, J., Bowsher, J., & Yin, F. (2011). SU‐C‐214‐06: Noise Power Properties of a Dual‐Detector Cone‐Beam CT System. In Medical Physics (Vol. 38, p. 3373). https://doi.org/10.1118/1.3611484
li, H., W. Giles, J. Roper, J. Bowsher, and F. Yin. “SU‐C‐214‐06: Noise Power Properties of a Dual‐Detector Cone‐Beam CT System.” In Medical Physics, 38:3373, 2011. https://doi.org/10.1118/1.3611484.
li H, Giles W, Roper J, Bowsher J, Yin F. SU‐C‐214‐06: Noise Power Properties of a Dual‐Detector Cone‐Beam CT System. In: Medical Physics. 2011. p. 3373.
li, H., et al. “SU‐C‐214‐06: Noise Power Properties of a Dual‐Detector Cone‐Beam CT System.” Medical Physics, vol. 38, no. 6, 2011, p. 3373. Scopus, doi:10.1118/1.3611484.
li H, Giles W, Roper J, Bowsher J, Yin F. SU‐C‐214‐06: Noise Power Properties of a Dual‐Detector Cone‐Beam CT System. Medical Physics. 2011. p. 3373.

Published In

Medical Physics

DOI

ISSN

0094-2405

Publication Date

January 1, 2011

Volume

38

Issue

6

Start / End Page

3373

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences