SU‐E‐T‐291: How Many Sets of Four‐Dimensional Computed Tomography (4DCT) Images Are Needed to Determine the Internal Target Volume (ITV) for Lung Radiation Therapy?

Publication ,  Journal Article
Cao, J; Cui, Y; Werner‐wasik, M; Champ, C; Liu, H; Xiao, Y; yu, Y
Published in: Medical Physics
January 1, 2011

Purpose: For the treatment of patients with lung cancer, internal target volume (ITV) is frequently determined by contouring of gross tumor volumes (GTV) on 10 phases of a four‐dimensional computed tomography (4DCT) scan. This study investigated the possibility of generating ITV by using selective phases of a 4DCT scan. Methods: The 4DCT scans of 20 patients with lung cancer were included in this study. GTVs were contoured on all 10 phases in Focal4D (CMS, St. Louis, MO). Different ITVs were derived by encompassing volumes of contours from selective phases. ITV10 was derived from contouring GTV on all 10 phases and served as the gold standard. All the other ITVs were smaller and within ITV10. The ratios of the volume of ITVs to ITV10 were calculated and used as a criterion to determine the similarity of ITVs to ITV10. ITV2 represented the ITV derived by using end of inhalation and end of exhalation (0%+50%). ITV3E was derived from contouring the three phases at end‐inhalation, mid‐exhalation, end‐exhalation (0%+20%+50%). ITV3I was derived from contouring the three phases at end‐inhalation, mid‐inhalation, end‐exhalation (0%+70%+50%). ITV4 was created by contouring the fours phases at end‐inhalation, mid‐inhalation, end‐exhalation, mid‐exhalation (0%+20%+50%+70%). ITV6E was derived from contouring the six consecutive phases during exhalation (0%+10%+20%+30%+40%+50%). ITV6I was derived from contouring the six consecutive phases during inhalation (50%+60%+70%+80%+90%+0%). Results: ITV6I showed excellent agreement with ITV10 (Volume ratio ITV6I/ITV10=0.975). ITV4 and ITV6E showed good agreement with ITV10 (ITV6E/ITV10=0.939, ITV4/ITV10=0.944). The volume ratio ITV3I/ITV10 and ITV3E/ITV10 was 0.927 and 0.906 respectively. ITV2 did not agree well with ITV10 (ITV2/ITV10 =0.888). Conclusions: Contouring all phases during inhalation will give a good estimate of the internal target volume, while helping to minimize the clinical load and work time during treatment planning. However, the ITV will be underestimated if only contouring on two extreme phases. © 2011, American Association of Physicists in Medicine. All rights reserved.

Duke Scholars

Published In

Medical Physics

DOI

ISSN

0094-2405

Publication Date

January 1, 2011

Volume

38

Issue

6

Start / End Page

3554

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Cao, J., Cui, Y., Werner‐wasik, M., Champ, C., Liu, H., Xiao, Y., & yu, Y. (2011). SU‐E‐T‐291: How Many Sets of Four‐Dimensional Computed Tomography (4DCT) Images Are Needed to Determine the Internal Target Volume (ITV) for Lung Radiation Therapy? Medical Physics, 38(6), 3554. https://doi.org/10.1118/1.3612242
Cao, J., Y. Cui, M. Werner‐wasik, C. Champ, H. Liu, Y. Xiao, and Y. yu. “SU‐E‐T‐291: How Many Sets of Four‐Dimensional Computed Tomography (4DCT) Images Are Needed to Determine the Internal Target Volume (ITV) for Lung Radiation Therapy?Medical Physics 38, no. 6 (January 1, 2011): 3554. https://doi.org/10.1118/1.3612242.

Published In

Medical Physics

DOI

ISSN

0094-2405

Publication Date

January 1, 2011

Volume

38

Issue

6

Start / End Page

3554

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences