SU‐FF‐J‐55: Cumulative Dose Calculation Using Deformable Image Registration

Publication ,  Journal Article
Wang, H; O'daniel, J; Ahamad, A; Garden, A; Mohan, R; Dong, L
Published in: Medical Physics
January 1, 2005

Purpose: To use deformable image registration to calculate cumulative dose distributions received by a radiotherapy patient in order to evaluate the dosimetric impact of anatomical variations during the course of treatment. Method and Materials: An intensity‐based deformable registration algorithm was developed to register the anatomy between the planning CT image and the daily CT images acquired from an in‐room CT‐on‐rails system. After the transformation from daily CT to planning CT was found, daily treatment doses delivered to an organ can be meaningfully accumulated. For one head‐and‐neck patient, the treatment plan was transferred to 15 daily CT scans using bony registration, and the dose distributions were calculated for the daily anatomy without daily setup errors. Using deformable image registration, these daily dose distributions were mapped back to the planning CT image. The cumulative dose was calculated and compared to the original plan using dose‐volume histograms (DVHs). Results: The dose delivered to the patient had minimal changes from the plan. Dose coverage for clinical target volumes at 70Gy, 63Gy, and 56Gy, left and right parotids at 25Gy, and mandible at 70Gy were evaluated. At these dose levels, the DVHs showed less than 1% difference, except for the left parotid, which had a 6% volume difference. The maximum dose in brainstem was 1.4% less than planned, the maximum dose in spinal cord was 2.2% higher than planned. The mean doses in left and right parotid were 4.4% higher and 2.5% lower than planned. Conclusion: In this case, we found little dosimetric differences due to changing anatomy during the course of treatment. Future studies will include daily setup errors. Deformable image registration is proven to be an effective approach for calculating cumulative dose distributions delivered to the patient, which can be used to evaluate the quality of treatment execution. © 2005, American Association of Physicists in Medicine. All rights reserved.

Duke Scholars

Published In

Medical Physics

DOI

ISSN

0094-2405

Publication Date

January 1, 2005

Volume

32

Issue

6

Start / End Page

1932

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Wang, H., O’daniel, J., Ahamad, A., Garden, A., Mohan, R., & Dong, L. (2005). SU‐FF‐J‐55: Cumulative Dose Calculation Using Deformable Image Registration. Medical Physics, 32(6), 1932. https://doi.org/10.1118/1.1997601
Wang, H., J. O’daniel, A. Ahamad, A. Garden, R. Mohan, and L. Dong. “SU‐FF‐J‐55: Cumulative Dose Calculation Using Deformable Image Registration.” Medical Physics 32, no. 6 (January 1, 2005): 1932. https://doi.org/10.1118/1.1997601.
Wang H, O’daniel J, Ahamad A, Garden A, Mohan R, Dong L. SU‐FF‐J‐55: Cumulative Dose Calculation Using Deformable Image Registration. Medical Physics. 2005 Jan 1;32(6):1932.
Wang, H., et al. “SU‐FF‐J‐55: Cumulative Dose Calculation Using Deformable Image Registration.” Medical Physics, vol. 32, no. 6, Jan. 2005, p. 1932. Scopus, doi:10.1118/1.1997601.
Wang H, O’daniel J, Ahamad A, Garden A, Mohan R, Dong L. SU‐FF‐J‐55: Cumulative Dose Calculation Using Deformable Image Registration. Medical Physics. 2005 Jan 1;32(6):1932.

Published In

Medical Physics

DOI

ISSN

0094-2405

Publication Date

January 1, 2005

Volume

32

Issue

6

Start / End Page

1932

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences