TU‐C‐BRB‐01: A Method to Determine Measured Dose‐Volume‐Histograms (DVH) in Patient from 3D Dose Measurement in Phantom

Publication ,  Conference
Oldham, M; Thomas, A
Published in: Medical Physics
January 1, 2011

Purpose: Three‐dimensional (3D) dosimetry systems are rapidly improving, and provide vastly more data and comprehensive QA than can be achieved with conventional dosimetry systems. New challenges emerge including how best to utilize this data. Here we present a method to transform the measured 3D dose in phantom, back to the planning CT, such that measured patient DVH's can be obtained. The significance is the method enables clinical interpretation of QA, through comparison of planned and measured DVH in patient. Methods: The DLOS/Presage 3D dosimetry system was used to verify the dose delivered for 6 stereotactic, fractionated, base‐of‐ skull radiosurgery treatments. Each plan was recalculated (fluence maps unchanged) and delivered to the RPC H&N IMRT credentialing phantom, containing a cylindrical Presage dosimeter 10cm diameter. The measured and planned dose distributions were compared in phantom. The measured dose‐distributions were then transformed back to the planning CT's, using an algorithm that comprehensively models heterogeneity differences. Measured and planned DVH and dose distributions were compared in patient. Results: Measured dose distributions with 2mm3 isotropic resolution were acquired for all 6 test cases. Excellent agreement was found between the measured and planned dose‐distributions in the phantom. Average 3D gamma passing rate (3%, 3mm criteria) was 95%. When the distributions were transformed back to the planning CT, measured DVHs showed close agreement with the planned DVH for all cases. Differences were observed, however, and will be discussed. The accuracy of the transform algorithm was investigated in simulations. Conclusions: In the event of a delivery error, the uncertainty in the transform algorithm is small (< 1%), significantly less than the magnitude of error to be detected. The DLOS/Presage system performed at a consistently high level, consistent with prior benchmarking studies. The ability to generate measured patient DVH's represents an important advance in treatment verification. © 2011, American Association of Physicists in Medicine. All rights reserved.

Duke Scholars

Published In

Medical Physics

DOI

ISSN

0094-2405

Publication Date

January 1, 2011

Volume

38

Issue

6

Start / End Page

3753

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Oldham, M., & Thomas, A. (2011). TU‐C‐BRB‐01: A Method to Determine Measured Dose‐Volume‐Histograms (DVH) in Patient from 3D Dose Measurement in Phantom. In Medical Physics (Vol. 38, p. 3753). https://doi.org/10.1118/1.3613121
Oldham, M., and A. Thomas. “TU‐C‐BRB‐01: A Method to Determine Measured Dose‐Volume‐Histograms (DVH) in Patient from 3D Dose Measurement in Phantom.” In Medical Physics, 38:3753, 2011. https://doi.org/10.1118/1.3613121.
Oldham, M., and A. Thomas. “TU‐C‐BRB‐01: A Method to Determine Measured Dose‐Volume‐Histograms (DVH) in Patient from 3D Dose Measurement in Phantom.” Medical Physics, vol. 38, no. 6, 2011, p. 3753. Scopus, doi:10.1118/1.3613121.

Published In

Medical Physics

DOI

ISSN

0094-2405

Publication Date

January 1, 2011

Volume

38

Issue

6

Start / End Page

3753

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences