Multicenter Study on the Analytical Performance of a New Point-of-Care Blood Gas Analyzer

Publication ,  Journal Article
Boldt, J; Goerlach-Graw, A; Halwachs-Baumann, G; Hindinger, J; Leinberger, R; Luebke, B; Nagel, D; Normand, H; Quintel, M; Riegebauer, J ...
Published in: Plastic Surgical Nursing
January 1, 2003

A multicenter study was carried out to investigate the analytical performance characteristics of the new blood gas analyzer, Roche OMNI C, in a clinical setting. In method comparison experiments, all results with Roche OMNI C were at least in good agreement with the routine laboratory comparison methods; typical correlation factors were above 0.92 for all parameters and above 0.98 for Po2Pco2and pH. In tonometry experiments, the recovery was 100% ± 2% with the exception of 1 concentration level with Pco2. Day-to-day imprecision for both controls and blood samples was very good, with coefficients of variation for most parameters below 1.6% (controls) and at or below 1.3% (blood samples). Overall, Roche OMNI C showed convincing analytical performance results in imprecision testing, tonometry, and method comparison experiments, and compared well with established routine analyzers. Its easy-to-use concept, low maintenance, and the possibility of automated quality control fit well into the critical care/point-of-care setting. © 2003 Lippincott Williams & Wilkins, Inc.

Duke Scholars

Published In

Plastic Surgical Nursing

DOI

EISSN

1550-1841

ISSN

0741-5206

Publication Date

January 1, 2003

Volume

2

Issue

3

Start / End Page

214 / 219

Related Subject Headings

  • Nursing
  • 1110 Nursing
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Boldt, J., Goerlach-Graw, A., Halwachs-Baumann, G., Hindinger, J., Leinberger, R., Luebke, B., … Zerback, R. (2003). Multicenter Study on the Analytical Performance of a New Point-of-Care Blood Gas Analyzer. Plastic Surgical Nursing, 2(3), 214–219. https://doi.org/10.1097/00134384-200309000-00012
Boldt, J., A. Goerlach-Graw, G. Halwachs-Baumann, J. Hindinger, R. Leinberger, B. Luebke, D. Nagel, et al. “Multicenter Study on the Analytical Performance of a New Point-of-Care Blood Gas Analyzer.” Plastic Surgical Nursing 2, no. 3 (January 1, 2003): 214–19. https://doi.org/10.1097/00134384-200309000-00012.
Boldt J, Goerlach-Graw A, Halwachs-Baumann G, Hindinger J, Leinberger R, Luebke B, et al. Multicenter Study on the Analytical Performance of a New Point-of-Care Blood Gas Analyzer. Plastic Surgical Nursing. 2003 Jan 1;2(3):214–9.
Boldt, J., et al. “Multicenter Study on the Analytical Performance of a New Point-of-Care Blood Gas Analyzer.” Plastic Surgical Nursing, vol. 2, no. 3, Jan. 2003, pp. 214–19. Scopus, doi:10.1097/00134384-200309000-00012.
Boldt J, Goerlach-Graw A, Halwachs-Baumann G, Hindinger J, Leinberger R, Luebke B, Nagel D, Normand H, Quintel M, Riegebauer J, Semmelrock HJ, Toffaletti J, Zerback R. Multicenter Study on the Analytical Performance of a New Point-of-Care Blood Gas Analyzer. Plastic Surgical Nursing. 2003 Jan 1;2(3):214–219.

Published In

Plastic Surgical Nursing

DOI

EISSN

1550-1841

ISSN

0741-5206

Publication Date

January 1, 2003

Volume

2

Issue

3

Start / End Page

214 / 219

Related Subject Headings

  • Nursing
  • 1110 Nursing