In vivo fluorescein staining of SI-30NB silicone intraocular lens.

Publication ,  Journal Article
Grewal, SPS; Jain, R; Grewal, D; Gupta, R
Published in: J Cataract Refract Surg
January 2007

We report a case of a 48-year-old pseudophakic woman who presented 3 weeks after Heidelberg retinal angiography using intravenous sodium fluorescein 2%. Bilateral retinal vasculitis with severe retinal ischemia and extensive capillary dropouts had been diagnosed. Anterior segment examination revealed green staining on the silicone optic of the 3-piece SI-30NB intraocular lens (IOL) (AMO), with no cell or flare in the aqueous humor. The anterior and posterior capsules were not stained. The patient did not report dark vision, double vision, or altered color vision. The anterior and posterior IOL surfaces demonstrated an autofluorescence at the time of fundus photography, which persisted to the 6-week examination although there were no symptoms. This is suggestive of deposits of sodium fluorescein on the IOL surface following angiography.

Duke Scholars

Published In

J Cataract Refract Surg

DOI

ISSN

0886-3350

Publication Date

January 2007

Volume

33

Issue

1

Start / End Page

156 / 158

Location

United States

Related Subject Headings

  • Staining and Labeling
  • Silicone Elastomers
  • Pseudophakia
  • Ophthalmology & Optometry
  • Middle Aged
  • Lenses, Intraocular
  • Humans
  • Fluorescence
  • Fluorescein Angiography
  • Fluorescein
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Grewal, S. P. S., Jain, R., Grewal, D., & Gupta, R. (2007). In vivo fluorescein staining of SI-30NB silicone intraocular lens. J Cataract Refract Surg, 33(1), 156–158. https://doi.org/10.1016/j.jcrs.2006.07.046
Grewal, Satinder Pal Singh, Rajeev Jain, Dilraj Grewal, and Rajeev Gupta. “In vivo fluorescein staining of SI-30NB silicone intraocular lens.J Cataract Refract Surg 33, no. 1 (January 2007): 156–58. https://doi.org/10.1016/j.jcrs.2006.07.046.
Grewal SPS, Jain R, Grewal D, Gupta R. In vivo fluorescein staining of SI-30NB silicone intraocular lens. J Cataract Refract Surg. 2007 Jan;33(1):156–8.
Grewal, Satinder Pal Singh, et al. “In vivo fluorescein staining of SI-30NB silicone intraocular lens.J Cataract Refract Surg, vol. 33, no. 1, Jan. 2007, pp. 156–58. Pubmed, doi:10.1016/j.jcrs.2006.07.046.
Grewal SPS, Jain R, Grewal D, Gupta R. In vivo fluorescein staining of SI-30NB silicone intraocular lens. J Cataract Refract Surg. 2007 Jan;33(1):156–158.
Journal cover image

Published In

J Cataract Refract Surg

DOI

ISSN

0886-3350

Publication Date

January 2007

Volume

33

Issue

1

Start / End Page

156 / 158

Location

United States

Related Subject Headings

  • Staining and Labeling
  • Silicone Elastomers
  • Pseudophakia
  • Ophthalmology & Optometry
  • Middle Aged
  • Lenses, Intraocular
  • Humans
  • Fluorescence
  • Fluorescein Angiography
  • Fluorescein