Skip to main content

Heartmate III Replacement for Recurring Left Ventricular Assist Device Pump Thrombosis.

Publication ,  Journal Article
Barac, YD; Schroder, JN; Daneshmand, MA; Patel, CB; Milano, CA
Published in: ASAIO J
2018

Left ventricular assist devices (LVADs) are being used widely to support patients with advanced systolic heart failure. Some of these patients will need more than one LVAD replacement due to pump thrombosis. The Heartmate III LVAD (Abbott Inc, Chicago, IL) recently has been shown to have a very low incidence of pump thrombosis. In this article, we describe cases of patients with multiple pump thrombosis events, who were successfully replaced with the Heartmate III.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

ASAIO J

DOI

EISSN

1538-943X

Publication Date

2018

Volume

64

Issue

3

Start / End Page

424 / 426

Location

United States

Related Subject Headings

  • Thrombosis
  • Reoperation
  • Middle Aged
  • Male
  • Incidence
  • Humans
  • Heart-Assist Devices
  • Heart Failure
  • Female
  • Equipment Failure
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Barac, Y. D., Schroder, J. N., Daneshmand, M. A., Patel, C. B., & Milano, C. A. (2018). Heartmate III Replacement for Recurring Left Ventricular Assist Device Pump Thrombosis. ASAIO J, 64(3), 424–426. https://doi.org/10.1097/MAT.0000000000000713
Barac, Yaron D., Jacob N. Schroder, Mani A. Daneshmand, Chetan B. Patel, and Carmelo A. Milano. “Heartmate III Replacement for Recurring Left Ventricular Assist Device Pump Thrombosis.ASAIO J 64, no. 3 (2018): 424–26. https://doi.org/10.1097/MAT.0000000000000713.
Barac YD, Schroder JN, Daneshmand MA, Patel CB, Milano CA. Heartmate III Replacement for Recurring Left Ventricular Assist Device Pump Thrombosis. ASAIO J. 2018;64(3):424–6.
Barac, Yaron D., et al. “Heartmate III Replacement for Recurring Left Ventricular Assist Device Pump Thrombosis.ASAIO J, vol. 64, no. 3, 2018, pp. 424–26. Pubmed, doi:10.1097/MAT.0000000000000713.
Barac YD, Schroder JN, Daneshmand MA, Patel CB, Milano CA. Heartmate III Replacement for Recurring Left Ventricular Assist Device Pump Thrombosis. ASAIO J. 2018;64(3):424–426.

Published In

ASAIO J

DOI

EISSN

1538-943X

Publication Date

2018

Volume

64

Issue

3

Start / End Page

424 / 426

Location

United States

Related Subject Headings

  • Thrombosis
  • Reoperation
  • Middle Aged
  • Male
  • Incidence
  • Humans
  • Heart-Assist Devices
  • Heart Failure
  • Female
  • Equipment Failure