Skip to main content

Bearing Surfaces for Total Hip Arthroplasty.

Publication ,  Journal Article
Lachiewicz, PF; Kleeman, LT; Seyler, T
Published in: J Am Acad Orthop Surg
January 15, 2018

Metal-on-highly cross-linked polyethylene is considered the preferred bearing surface for conventional total hip arthroplasty because of its safety profile and excellent results in the first 10 to 15 years of use. However, with younger patient age, activity expectations increase, and the life expectancy of patients with total hip arthroplasty also has increased, so interest remains in other bearing couples. These other options include the use of various ceramic composites for the femoral head on highly cross-linked polyethylene, the so-called second-generation antioxidant polyethylenes, and ceramic acetabular liners. Several of these bearing couples have shown excellent wear rates in vitro, and short-term clinical studies have demonstrated favorable wear and safety results. It is uncertain whether any of these bearing couples should be adopted at present. Understanding the unique properties and possible complications of these bearing couples is critical for appropriate implant selection.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

J Am Acad Orthop Surg

DOI

EISSN

1940-5480

Publication Date

January 15, 2018

Volume

26

Issue

2

Start / End Page

45 / 57

Location

United States

Related Subject Headings

  • Prosthesis Failure
  • Prosthesis Design
  • Orthopedics
  • Humans
  • Hip Prosthesis
  • Arthroplasty, Replacement, Hip
  • 3202 Clinical sciences
  • 1103 Clinical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Lachiewicz, P. F., Kleeman, L. T., & Seyler, T. (2018). Bearing Surfaces for Total Hip Arthroplasty. J Am Acad Orthop Surg, 26(2), 45–57. https://doi.org/10.5435/JAAOS-D-15-00754
Lachiewicz, Paul F., Lindsay T. Kleeman, and Thorsten Seyler. “Bearing Surfaces for Total Hip Arthroplasty.J Am Acad Orthop Surg 26, no. 2 (January 15, 2018): 45–57. https://doi.org/10.5435/JAAOS-D-15-00754.
Lachiewicz PF, Kleeman LT, Seyler T. Bearing Surfaces for Total Hip Arthroplasty. J Am Acad Orthop Surg. 2018 Jan 15;26(2):45–57.
Lachiewicz, Paul F., et al. “Bearing Surfaces for Total Hip Arthroplasty.J Am Acad Orthop Surg, vol. 26, no. 2, Jan. 2018, pp. 45–57. Pubmed, doi:10.5435/JAAOS-D-15-00754.
Lachiewicz PF, Kleeman LT, Seyler T. Bearing Surfaces for Total Hip Arthroplasty. J Am Acad Orthop Surg. 2018 Jan 15;26(2):45–57.

Published In

J Am Acad Orthop Surg

DOI

EISSN

1940-5480

Publication Date

January 15, 2018

Volume

26

Issue

2

Start / End Page

45 / 57

Location

United States

Related Subject Headings

  • Prosthesis Failure
  • Prosthesis Design
  • Orthopedics
  • Humans
  • Hip Prosthesis
  • Arthroplasty, Replacement, Hip
  • 3202 Clinical sciences
  • 1103 Clinical Sciences