Independent calculation of monitor units for VMAT and SPORT.

Publication ,  Journal Article
Chen, X; Bush, K; Ding, A; Xing, L
Published in: Medical physics
February 2015

Dose and monitor units (MUs) represent two important facets of a radiation therapy treatment. In current practice, verification of a treatment plan is commonly done in dose domain, in which a phantom measurement or forward dose calculation is performed to examine the dosimetric accuracy and the MU settings of a given treatment plan. While it is desirable to verify directly the MU settings, a computational framework for obtaining the MU values from a known dose distribution has yet to be developed. This work presents a strategy to calculate independently the MUs from a given dose distribution of volumetric modulated arc therapy (VMAT) and station parameter optimized radiation therapy (SPORT).The dose at a point can be expressed as a sum of contributions from all the station points (or control points). This relationship forms the basis of the proposed MU verification technique. To proceed, the authors first obtain the matrix elements which characterize the dosimetric contribution of the involved station points by computing the doses at a series of voxels, typically on the prescription surface of the VMAT/SPORT treatment plan, with unit MU setting for all the station points. An in-house Monte Carlo (MC) software is used for the dose matrix calculation. The MUs of the station points are then derived by minimizing the least-squares difference between doses computed by the treatment planning system (TPS) and that of the MC for the selected set of voxels on the prescription surface. The technique is applied to 16 clinical cases with a variety of energies, disease sites, and TPS dose calculation algorithms.For all plans except the lung cases with large tissue density inhomogeneity, the independently computed MUs agree with that of TPS to within 2.7% for all the station points. In the dose domain, no significant difference between the MC and Eclipse Anisotropic Analytical Algorithm (AAA) dose distribution is found in terms of isodose contours, dose profiles, gamma index, and dose volume histogram (DVH) for these cases. For the lung cases, the MC-calculated MUs differ significantly from that of the treatment plan computed using AAA. However, the discrepancies are reduced to within 3% when the TPS dose calculation algorithm is switched to a transport equation-based technique (Acuros™). Comparison in the dose domain between the MC and Eclipse AAA/Acuros calculation yields conclusion consistent with the MU calculation.A computational framework relating the MU and dose domains has been established. The framework does not only enable them to verify the MU values of the involved station points of a VMAT plan directly in the MU domain but also provide a much needed mechanism to adaptively modify the MU values of the station points in accordance to a specific change in the dose domain.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Medical physics

DOI

EISSN

2473-4209

ISSN

0094-2405

Publication Date

February 2015

Volume

42

Issue

2

Start / End Page

918 / 924

Related Subject Headings

  • Radiotherapy, Intensity-Modulated
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Monte Carlo Method
  • Humans
  • Dose Fractionation, Radiation
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Chen, X., Bush, K., Ding, A., & Xing, L. (2015). Independent calculation of monitor units for VMAT and SPORT. Medical Physics, 42(2), 918–924. https://doi.org/10.1118/1.4906185
Chen, Xin, Karl Bush, Aiping Ding, and Lei Xing. “Independent calculation of monitor units for VMAT and SPORT.Medical Physics 42, no. 2 (February 2015): 918–24. https://doi.org/10.1118/1.4906185.
Chen X, Bush K, Ding A, Xing L. Independent calculation of monitor units for VMAT and SPORT. Medical physics. 2015 Feb;42(2):918–24.
Chen, Xin, et al. “Independent calculation of monitor units for VMAT and SPORT.Medical Physics, vol. 42, no. 2, Feb. 2015, pp. 918–24. Epmc, doi:10.1118/1.4906185.
Chen X, Bush K, Ding A, Xing L. Independent calculation of monitor units for VMAT and SPORT. Medical physics. 2015 Feb;42(2):918–924.

Published In

Medical physics

DOI

EISSN

2473-4209

ISSN

0094-2405

Publication Date

February 2015

Volume

42

Issue

2

Start / End Page

918 / 924

Related Subject Headings

  • Radiotherapy, Intensity-Modulated
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Monte Carlo Method
  • Humans
  • Dose Fractionation, Radiation
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering