Skip to main content
Journal cover image

Stereoselective analysis of bupropion and hydroxybupropion in human plasma and urine by LC/MS/MS.

Publication ,  Journal Article
Coles, R; Kharasch, ED
Published in: J Chromatogr B Analyt Technol Biomed Life Sci
September 15, 2007

A sensitive, stereoselective assay using solid phase extraction and LC-MS-MS was developed and validated for the analysis of (R)- and (S)-bupropion and its major metabolite (R,R)- and (S,S)-hydroxybupropion in human plasma and urine. Plasma or glucuronidase-hydrolyzed urine was acidified, then extracted using a Waters Oasis MCX solid phase 96-well plate. HPLC separation used an alpha(1)-acid glycoprotein column, a gradient mobile phase of methanol and aqueous ammonium formate, and analytes were detected by electrospray ionization and multiple reaction monitoring with an API 4000 Qtrap. The assay was linear in plasma from 0.5 to 200 ng/ml and 2.5 to 1000 ng/ml in each bupropion and hydroxybupropion enantiomer, respectively. The assay was linear in urine from 5 to 2000 ng/ml and 25 to 10,000 ng/ml in each bupropion and hydroxybupropion enantiomer, respectively. Intra- and inter-day accuracy was >98% and intra- and inter-day coefficients of variations were less than 10% for all analytes and concentrations. The assay was applied to a subject dosed with racemic bupropion. The predominant enantiomers in both urine and plasma were (R)-bupropion and (R,R)-hydroxybupropion. This is the first LC-MS/MS assay to analyze the enantiomers of both bupropion and hydroxybupropion in plasma and urine.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

J Chromatogr B Analyt Technol Biomed Life Sci

DOI

ISSN

1570-0232

Publication Date

September 15, 2007

Volume

857

Issue

1

Start / End Page

67 / 75

Location

Netherlands

Related Subject Headings

  • Tandem Mass Spectrometry
  • Stereoisomerism
  • Spectrometry, Mass, Electrospray Ionization
  • Specimen Handling
  • Solid Phase Extraction
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Reference Standards
  • Humans
  • Chromatography, High Pressure Liquid
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Coles, R., & Kharasch, E. D. (2007). Stereoselective analysis of bupropion and hydroxybupropion in human plasma and urine by LC/MS/MS. J Chromatogr B Analyt Technol Biomed Life Sci, 857(1), 67–75. https://doi.org/10.1016/j.jchromb.2007.07.007
Coles, Rebecka, and Evan D. Kharasch. “Stereoselective analysis of bupropion and hydroxybupropion in human plasma and urine by LC/MS/MS.J Chromatogr B Analyt Technol Biomed Life Sci 857, no. 1 (September 15, 2007): 67–75. https://doi.org/10.1016/j.jchromb.2007.07.007.
Coles R, Kharasch ED. Stereoselective analysis of bupropion and hydroxybupropion in human plasma and urine by LC/MS/MS. J Chromatogr B Analyt Technol Biomed Life Sci. 2007 Sep 15;857(1):67–75.
Coles, Rebecka, and Evan D. Kharasch. “Stereoselective analysis of bupropion and hydroxybupropion in human plasma and urine by LC/MS/MS.J Chromatogr B Analyt Technol Biomed Life Sci, vol. 857, no. 1, Sept. 2007, pp. 67–75. Pubmed, doi:10.1016/j.jchromb.2007.07.007.
Coles R, Kharasch ED. Stereoselective analysis of bupropion and hydroxybupropion in human plasma and urine by LC/MS/MS. J Chromatogr B Analyt Technol Biomed Life Sci. 2007 Sep 15;857(1):67–75.
Journal cover image

Published In

J Chromatogr B Analyt Technol Biomed Life Sci

DOI

ISSN

1570-0232

Publication Date

September 15, 2007

Volume

857

Issue

1

Start / End Page

67 / 75

Location

Netherlands

Related Subject Headings

  • Tandem Mass Spectrometry
  • Stereoisomerism
  • Spectrometry, Mass, Electrospray Ionization
  • Specimen Handling
  • Solid Phase Extraction
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Reference Standards
  • Humans
  • Chromatography, High Pressure Liquid