Skip to main content

Comparison of Detection Limits of Fourth- and Fifth-Generation Combination HIV Antigen-Antibody, p24 Antigen, and Viral Load Assays on Diverse HIV Isolates.

Publication ,  Journal Article
Stone, M; Bainbridge, J; Sanchez, AM; Keating, SM; Pappas, A; Rountree, W; Todd, C; Bakkour, S; Manak, M; Peel, SA; Coombs, RW; Ramos, EM ...
Published in: J Clin Microbiol
August 2018

Detection of acute HIV infection is critical for HIV public health and diagnostics. Clinical fourth-generation antigen (Ag)/antibody (Ab) combination (combo) and p24 Ag immunoassays have enhanced detection of acute infection compared to Ab-alone assays but require ongoing evaluation with currently circulating diverse subtypes. Genetically and geographically diverse HIV clinical isolates were used to assess clinical HIV diagnostic, blood screening, and next-generation assays. Three-hundred-member panels of 20 serially diluted well-characterized antibody-negative HIV isolates for which the researchers were blind to the results (blind panels) were distributed to manufacturers and end-user labs to assess the relative analytic sensitivity of currently approved and preapproved clinical HIV fourth-generation Ag/Ab combo or p24 Ag-alone immunoassays for the detection of diverse subtypes. The limits of detection (LODs) of virus were estimated for different subtypes relative to confirmed viral loads. Analysis of immunoassay sensitivity was benchmarked against confirmed viral load measurements on the blind panel. On the basis of the proportion of positive results on 300 observations, all Ag/Ab combo and standard sensitivity p24 Ag assays performed similarly and within half-log LODs, illustrating the similar breadth of reactivity and diagnostic utility. Ultrasensitive p24 Ag assays achieved dramatically increased sensitivities, while the rapid combo assays performed poorly. The similar performance of the different commercially available fourth-generation assays on diverse subtypes supports their use in broad geographic settings with locally circulating HIV clades and recombinant strains. Next-generation preclinical ultrasensitive p24 Ag assays achieved dramatically improved sensitivity, while rapid fourth-generation assays performed poorly for p24 Ag detection.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

J Clin Microbiol

DOI

EISSN

1098-660X

Publication Date

August 2018

Volume

56

Issue

8

Location

United States

Related Subject Headings

  • Viral Load
  • Sensitivity and Specificity
  • Microbiology
  • Limit of Detection
  • Immunoassay
  • Humans
  • HIV Infections
  • HIV Core Protein p24
  • HIV Antigens
  • HIV Antibodies
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Stone, M., Bainbridge, J., Sanchez, A. M., Keating, S. M., Pappas, A., Rountree, W., … Busch, M. P. (2018). Comparison of Detection Limits of Fourth- and Fifth-Generation Combination HIV Antigen-Antibody, p24 Antigen, and Viral Load Assays on Diverse HIV Isolates. J Clin Microbiol, 56(8). https://doi.org/10.1128/JCM.02045-17
Stone, Mars, John Bainbridge, Ana M. Sanchez, Sheila M. Keating, Andrea Pappas, Wes Rountree, Chris Todd, et al. “Comparison of Detection Limits of Fourth- and Fifth-Generation Combination HIV Antigen-Antibody, p24 Antigen, and Viral Load Assays on Diverse HIV Isolates.J Clin Microbiol 56, no. 8 (August 2018). https://doi.org/10.1128/JCM.02045-17.
Stone M, Bainbridge J, Sanchez AM, Keating SM, Pappas A, Rountree W, et al. Comparison of Detection Limits of Fourth- and Fifth-Generation Combination HIV Antigen-Antibody, p24 Antigen, and Viral Load Assays on Diverse HIV Isolates. J Clin Microbiol. 2018 Aug;56(8).
Stone, Mars, et al. “Comparison of Detection Limits of Fourth- and Fifth-Generation Combination HIV Antigen-Antibody, p24 Antigen, and Viral Load Assays on Diverse HIV Isolates.J Clin Microbiol, vol. 56, no. 8, Aug. 2018. Pubmed, doi:10.1128/JCM.02045-17.
Stone M, Bainbridge J, Sanchez AM, Keating SM, Pappas A, Rountree W, Todd C, Bakkour S, Manak M, Peel SA, Coombs RW, Ramos EM, Shriver MK, Contestable P, Nair SV, Wilson DH, Stengelin M, Murphy G, Hewlett I, Denny TN, Busch MP. Comparison of Detection Limits of Fourth- and Fifth-Generation Combination HIV Antigen-Antibody, p24 Antigen, and Viral Load Assays on Diverse HIV Isolates. J Clin Microbiol. 2018 Aug;56(8).

Published In

J Clin Microbiol

DOI

EISSN

1098-660X

Publication Date

August 2018

Volume

56

Issue

8

Location

United States

Related Subject Headings

  • Viral Load
  • Sensitivity and Specificity
  • Microbiology
  • Limit of Detection
  • Immunoassay
  • Humans
  • HIV Infections
  • HIV Core Protein p24
  • HIV Antigens
  • HIV Antibodies