Rapid Antimicrobial Susceptibility Testing Using Forward Laser Light Scatter Technology.

Publication ,  Journal Article
Hayden, RT; Clinton, LK; Hewitt, C; Koyamatsu, T; Sun, Y; Jamison, G; Perkins, R; Tang, L; Pounds, S; Bankowski, MJ
Published in: J Clin Microbiol
November 2016

The delayed reporting of antimicrobial susceptibility testing remains a limiting factor in clinical decision-making in the treatment of bacterial infection. This study evaluates the use of forward laser light scatter (FLLS) to measure bacterial growth for the early determination of antimicrobial susceptibility. Three isolates each (two clinical isolates and one reference strain) of Staphylococcus aureus, Escherichia coli, and Pseudomonas aeruginosa were tested in triplicate using two commercial antimicrobial testing systems, the Vitek2 and the MicroScan MIC panel, to challenge the BacterioScan FLLS. The BacterioScan FLLS showed a high degree of categorical concordance with the commercial methods. Pairwise comparison with each commercial system serving as a reference standard showed 88.9% agreement with MicroScan (two minor errors) and 72.2% agreement with Vitek (five minor errors). FLLS using the BacterioScan system shows promise as a novel method for the rapid and accurate determination of antimicrobial susceptibility.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

J Clin Microbiol

DOI

EISSN

1098-660X

Publication Date

November 2016

Volume

54

Issue

11

Start / End Page

2701 / 2706

Location

United States

Related Subject Headings

  • Time Factors
  • Staphylococcus aureus
  • Pseudomonas aeruginosa
  • Pilot Projects
  • Microbiology
  • Microbial Sensitivity Tests
  • Lasers
  • Humans
  • Escherichia coli
  • Dynamic Light Scattering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Hayden, R. T., Clinton, L. K., Hewitt, C., Koyamatsu, T., Sun, Y., Jamison, G., … Bankowski, M. J. (2016). Rapid Antimicrobial Susceptibility Testing Using Forward Laser Light Scatter Technology. J Clin Microbiol, 54(11), 2701–2706. https://doi.org/10.1128/JCM.01475-16
Hayden, Randall T., Lani K. Clinton, Carolyn Hewitt, Terri Koyamatsu, Yilun Sun, Ginger Jamison, Rosalie Perkins, Li Tang, Stanley Pounds, and Matthew J. Bankowski. “Rapid Antimicrobial Susceptibility Testing Using Forward Laser Light Scatter Technology.J Clin Microbiol 54, no. 11 (November 2016): 2701–6. https://doi.org/10.1128/JCM.01475-16.
Hayden RT, Clinton LK, Hewitt C, Koyamatsu T, Sun Y, Jamison G, et al. Rapid Antimicrobial Susceptibility Testing Using Forward Laser Light Scatter Technology. J Clin Microbiol. 2016 Nov;54(11):2701–6.
Hayden, Randall T., et al. “Rapid Antimicrobial Susceptibility Testing Using Forward Laser Light Scatter Technology.J Clin Microbiol, vol. 54, no. 11, Nov. 2016, pp. 2701–06. Pubmed, doi:10.1128/JCM.01475-16.
Hayden RT, Clinton LK, Hewitt C, Koyamatsu T, Sun Y, Jamison G, Perkins R, Tang L, Pounds S, Bankowski MJ. Rapid Antimicrobial Susceptibility Testing Using Forward Laser Light Scatter Technology. J Clin Microbiol. 2016 Nov;54(11):2701–2706.

Published In

J Clin Microbiol

DOI

EISSN

1098-660X

Publication Date

November 2016

Volume

54

Issue

11

Start / End Page

2701 / 2706

Location

United States

Related Subject Headings

  • Time Factors
  • Staphylococcus aureus
  • Pseudomonas aeruginosa
  • Pilot Projects
  • Microbiology
  • Microbial Sensitivity Tests
  • Lasers
  • Humans
  • Escherichia coli
  • Dynamic Light Scattering