Skip to main content
Journal cover image

T2 hyperintensity of medial lemniscus: higher threshold application to ROI measurements is more accurate in predicting small vessel disease.

Publication ,  Journal Article
Hakky, MM; Erbay, KD; Brewer, E; Midle, JB; French, R; Erbay, SH
Published in: J Neuroimaging
July 2013

BACKGROUND: Medial lemniscus T2 hyperintensity (MLH) has been recently demonstrated as potential imaging marker for small vessel disease (SVD). Our purpose in this study is to improve accuracy of regions of interest (ROI) analysis for this imaging finding. METHODS AND METHODS: Two neuroradiologists retrospectively reviewed 103 consecutive outpatient brain MRI. Medial lemniscus signal in dorsal pons was evaluated; visually on FLAIR and with ROI on T2. Original MRI interpretations were divided into three categories; SVD, multiple sclerosis (MS), and nonspecific WM changes (non). RESULTS: Thirty-seven patients had SVD, 14 patients had MS, 52 had Non. Visual MLH was seen exclusively with SVD and was generally bilateral. Patients with visual MLH belonged to advanced SVD by imaging and clinical parameters. Compared to visual data, ROI analyses of MLH has been known to be compounded by false positives and negatives at low threshold (20% of adjacent to normal brainstem signal). With application of higher ROI threshold (25%), false positives were eliminated but false negatives increased. ROI analyses of MLH by experienced neuroradiologist were more reliable. CONCLUSION: MLH seen on high threshold ROI analysis is a reliable radiologic marker in predicting SVD. ROI analysis of MLH should be performed by an experienced neuroradiologist.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

J Neuroimaging

DOI

EISSN

1552-6569

Publication Date

July 2013

Volume

23

Issue

3

Start / End Page

345 / 351

Location

United States

Related Subject Headings

  • White Matter
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Neurology & Neurosurgery
  • Multiple Sclerosis
  • Middle Aged
  • Microvessels
  • Medulla Oblongata
  • Male
  • Magnetic Resonance Imaging
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Hakky, M. M., Erbay, K. D., Brewer, E., Midle, J. B., French, R., & Erbay, S. H. (2013). T2 hyperintensity of medial lemniscus: higher threshold application to ROI measurements is more accurate in predicting small vessel disease. J Neuroimaging, 23(3), 345–351. https://doi.org/10.1111/jon.12011
Hakky, Michael M., Kaan D. Erbay, Edward Brewer, Jennifer B. Midle, Robert French, and Sami H. Erbay. “T2 hyperintensity of medial lemniscus: higher threshold application to ROI measurements is more accurate in predicting small vessel disease.J Neuroimaging 23, no. 3 (July 2013): 345–51. https://doi.org/10.1111/jon.12011.
Hakky MM, Erbay KD, Brewer E, Midle JB, French R, Erbay SH. T2 hyperintensity of medial lemniscus: higher threshold application to ROI measurements is more accurate in predicting small vessel disease. J Neuroimaging. 2013 Jul;23(3):345–51.
Hakky, Michael M., et al. “T2 hyperintensity of medial lemniscus: higher threshold application to ROI measurements is more accurate in predicting small vessel disease.J Neuroimaging, vol. 23, no. 3, July 2013, pp. 345–51. Pubmed, doi:10.1111/jon.12011.
Hakky MM, Erbay KD, Brewer E, Midle JB, French R, Erbay SH. T2 hyperintensity of medial lemniscus: higher threshold application to ROI measurements is more accurate in predicting small vessel disease. J Neuroimaging. 2013 Jul;23(3):345–351.
Journal cover image

Published In

J Neuroimaging

DOI

EISSN

1552-6569

Publication Date

July 2013

Volume

23

Issue

3

Start / End Page

345 / 351

Location

United States

Related Subject Headings

  • White Matter
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Neurology & Neurosurgery
  • Multiple Sclerosis
  • Middle Aged
  • Microvessels
  • Medulla Oblongata
  • Male
  • Magnetic Resonance Imaging