Skip to main content
Journal cover image

Agreement among spectral-domain optical coherence tomography instruments for assessing retinal nerve fiber layer thickness

Publication ,  Journal Article
Leite, MT; Rao, HL; Weinreb, RN; Zangwill, LM; Bowd, C; Sample, PA; Tafreshi, A; Medeiros, FA
Published in: American Journal of Ophthalmology
January 1, 2011

Purpose To assess the agreement of parapapillary retinal nerve fiber layer (RNFL) thickness measurements among 3 spectral-domain optical coherence tomography (SD-OCT) instruments. Design Observational, cross-sectional study. Methods Three hundred thirty eyes (88 with glaucoma, 206 glaucoma suspects, 36 healthy) from 208 individuals enrolled in the Diagnostic Innovations in Glaucoma Study (DIGS) were imaged using RTVue, Spectralis and Cirrus in a single visit. Agreement among RNFL thickness measurements was assessed using Bland-Altman plots. The influence of age, axial length, disc size, race, spherical equivalent, and disease severity on the pairwise agreements between different instruments was assessed by regression analysis. Results Although RNFL thickness measurements between different instruments were highly correlated, Bland-Altman analyses indicated the presence of fixed and proportional biases for most of the pairwise agreements. In general, RTVue measurements tended to be thicker than Spectralis and Cirrus measurements. The agreement in average RNFL thickness measurements between RTVue and Spectralis was affected by age (P = .001) and spherical equivalent (P < .001), whereas the agreement between Spectralis and Cirrus was affected by axial length (P = .004) and spherical equivalent (P < .001). Disease severity influenced the agreement between Spectralis and both RTVue and Cirrus (P = .001). Disc area and race did not influence the agreement among the devices. Conclusions RNFL thickness measurements obtained by different SD-OCT instruments were not entirely compatible and therefore they should not be used interchangeably. This may be attributable in part to differences in RNFL detection algorithms. Comparisons with histologic measurements could determine which technique is most accurate.

Duke Scholars

Published In

American Journal of Ophthalmology

DOI

ISSN

0002-9394

Publication Date

January 1, 2011

Volume

151

Issue

1

Related Subject Headings

  • Ophthalmology & Optometry
  • 3212 Ophthalmology and optometry
  • 1117 Public Health and Health Services
  • 1113 Opthalmology and Optometry
  • 1103 Clinical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Leite, M. T., Rao, H. L., Weinreb, R. N., Zangwill, L. M., Bowd, C., Sample, P. A., … Medeiros, F. A. (2011). Agreement among spectral-domain optical coherence tomography instruments for assessing retinal nerve fiber layer thickness. American Journal of Ophthalmology, 151(1). https://doi.org/10.1016/j.ajo.2010.06.041
Leite, M. T., H. L. Rao, R. N. Weinreb, L. M. Zangwill, C. Bowd, P. A. Sample, A. Tafreshi, and F. A. Medeiros. “Agreement among spectral-domain optical coherence tomography instruments for assessing retinal nerve fiber layer thickness.” American Journal of Ophthalmology 151, no. 1 (January 1, 2011). https://doi.org/10.1016/j.ajo.2010.06.041.
Leite MT, Rao HL, Weinreb RN, Zangwill LM, Bowd C, Sample PA, et al. Agreement among spectral-domain optical coherence tomography instruments for assessing retinal nerve fiber layer thickness. American Journal of Ophthalmology. 2011 Jan 1;151(1).
Leite, M. T., et al. “Agreement among spectral-domain optical coherence tomography instruments for assessing retinal nerve fiber layer thickness.” American Journal of Ophthalmology, vol. 151, no. 1, Jan. 2011. Scopus, doi:10.1016/j.ajo.2010.06.041.
Leite MT, Rao HL, Weinreb RN, Zangwill LM, Bowd C, Sample PA, Tafreshi A, Medeiros FA. Agreement among spectral-domain optical coherence tomography instruments for assessing retinal nerve fiber layer thickness. American Journal of Ophthalmology. 2011 Jan 1;151(1).
Journal cover image

Published In

American Journal of Ophthalmology

DOI

ISSN

0002-9394

Publication Date

January 1, 2011

Volume

151

Issue

1

Related Subject Headings

  • Ophthalmology & Optometry
  • 3212 Ophthalmology and optometry
  • 1117 Public Health and Health Services
  • 1113 Opthalmology and Optometry
  • 1103 Clinical Sciences