Skip to main content
construction release_alert
Scholars@Duke will be undergoing maintenance April 11-15. Some features may be unavailable during this time.
cancel
Journal cover image

Determinants of agreement between the confocal scanning laser tomograph and standardized assessment of glaucomatous progression.

Publication ,  Journal Article
Vizzeri, G; Bowd, C; Weinreb, RN; Balasubramanian, M; Medeiros, FA; Sample, PA; Zangwill, LM
Published in: Ophthalmology
October 2010

PURPOSE: To estimate the agreement of confocal scanning laser tomograph (CSLT), topographic change analysis (TCA) with assessment of stereophotographs, and standard automated perimetry (SAP) for detecting glaucomatous progression and to identify factors associated with agreement between methods. DESIGN: Observational cohort study. PARTICIPANTS: We included 246 eyes of 167 glaucoma patients, glaucoma suspects, and ocular hypertensives. METHODS: We included CSLT series (n ≥ 4 tests; mean follow-up, 4 years), stereophotographs, and SAP results in the analysis. The number of progressors by guided progression analysis (GPA, "likely progression"), progressors by masked stereophotographs assessment and progressors by TCA as determined for 3 parameters related to the number of progressed superpixels within the disc margin was determined. Agreement between progression by each TCA parameter, stereophotographs and GPA was assessed using the Kappa test. Analysis of variance with post hoc analysis was applied to identify baseline factors including image quality (standard deviation of the mean topography), disc size and disease severity (pattern standard deviation [PSD] and cup area) associated with agreement/nonagreement between methods. MAIN OUTCOME MEASURES: Agreement in assessing glaucomatous progression between the methods including factors associated with agreement/nonagreement between methods. RESULTS: Agreement between progression by TCA and progression by stereophotographs and/or GPA was generally poor regardless of the TCA parameter and specificity cutoffs applied. For the parameters with the strongest agreement, cluster size in disc (CSIZE(disc)) and cluster area in disc (CAREA(disc)), kappa values were 0.16 (63.9%, agreement on 134 nonprogressing eyes and 23 progressing eyes) and 0.15 (64.1%, agreement on 135 nonprogressing eyes and 22 progressing eyes) at 99% cutoff. Most of the factors evaluated were not significantly associated with agreement/nonagreement between methods (all P > 0.07). However, SAP PSD was greater in the progressors by stereophotography only group compared with the progressors by TCA only group (5.8 ± 4.7 and 2.6 ± 2.2, respectively [P = 0.003] for CSIZE(disc) at 95% specificity and 5.4 ± 4.6 and 2.5 ± 2.3, respectively [P = 0.002] for CAREA(disc) at 99% specificity). CONCLUSIONS: Agreement for detection of longitudinal changes between TCA, stereophotography, and SAP GPA is poor. Progressors by stereophotography only tended to have more advanced disease at baseline than progressors by TCA only.

Duke Scholars

Published In

Ophthalmology

DOI

EISSN

1549-4713

Publication Date

October 2010

Volume

117

Issue

10

Start / End Page

1953 / 1959

Location

United States

Related Subject Headings

  • Visual Fields
  • Vision Disorders
  • Tomography
  • Prospective Studies
  • Photography
  • Optic Nerve Diseases
  • Optic Disk
  • Ophthalmology & Optometry
  • Ocular Hypertension
  • Middle Aged
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Vizzeri, G., Bowd, C., Weinreb, R. N., Balasubramanian, M., Medeiros, F. A., Sample, P. A., & Zangwill, L. M. (2010). Determinants of agreement between the confocal scanning laser tomograph and standardized assessment of glaucomatous progression. Ophthalmology, 117(10), 1953–1959. https://doi.org/10.1016/j.ophtha.2010.02.002
Vizzeri, Gianmarco, Christopher Bowd, Robert N. Weinreb, Madhusudhanan Balasubramanian, Felipe A. Medeiros, Pamela A. Sample, and Linda M. Zangwill. “Determinants of agreement between the confocal scanning laser tomograph and standardized assessment of glaucomatous progression.Ophthalmology 117, no. 10 (October 2010): 1953–59. https://doi.org/10.1016/j.ophtha.2010.02.002.
Vizzeri G, Bowd C, Weinreb RN, Balasubramanian M, Medeiros FA, Sample PA, et al. Determinants of agreement between the confocal scanning laser tomograph and standardized assessment of glaucomatous progression. Ophthalmology. 2010 Oct;117(10):1953–9.
Vizzeri, Gianmarco, et al. “Determinants of agreement between the confocal scanning laser tomograph and standardized assessment of glaucomatous progression.Ophthalmology, vol. 117, no. 10, Oct. 2010, pp. 1953–59. Pubmed, doi:10.1016/j.ophtha.2010.02.002.
Vizzeri G, Bowd C, Weinreb RN, Balasubramanian M, Medeiros FA, Sample PA, Zangwill LM. Determinants of agreement between the confocal scanning laser tomograph and standardized assessment of glaucomatous progression. Ophthalmology. 2010 Oct;117(10):1953–1959.
Journal cover image

Published In

Ophthalmology

DOI

EISSN

1549-4713

Publication Date

October 2010

Volume

117

Issue

10

Start / End Page

1953 / 1959

Location

United States

Related Subject Headings

  • Visual Fields
  • Vision Disorders
  • Tomography
  • Prospective Studies
  • Photography
  • Optic Nerve Diseases
  • Optic Disk
  • Ophthalmology & Optometry
  • Ocular Hypertension
  • Middle Aged