Skip to main content
Journal cover image

Effect of signal strength and improper alignment on the variability of stratus optical coherence tomography retinal nerve fiber layer thickness measurements.

Publication ,  Journal Article
Vizzeri, G; Bowd, C; Medeiros, FA; Weinreb, RN; Zangwill, LM
Published in: Am J Ophthalmol
August 2009

PURPOSE: To evaluate the effect of signal strength and improper scan alignment on retinal nerve fiber layer (RNFL) thickness measurement variability. DESIGN: Retrospective, longitudinal clinical study. METHODS: All eyes of healthy subjects with at least 2 fast RNFL scan sessions were selected from the Diagnostic Innovations in Glaucoma Study. The chronological first scan was considered to be the baseline. Absolute differences in signal strength and RNFL thickness measurements between baseline and subsequent scans were calculated. Regression analysis was conducted to assess whether signal strength and scan shifts along the horizontal (nasal-temporal) but not the vertical (superior-inferior) axis affect average RNFL thickness measurements. RESULTS: Ninety-four eyes of 94 subjects were included. All eyes were tested twice or more on the same visit, whereas 30 eyes were followed up longitudinally for 32.4 +/- 13.3 months (1 scan per annual follow-up). For quadrants, absolute differences from baseline were greater than for average RNFL thickness and were significantly larger for scans acquired on separate visits. Average RNFL thickness increased only when the difference between the nasal and temporal quadrants increased (R2 = 0.16; P < .0001), suggesting it may be affected by horizontal but not vertical scan shifts. Differences in signal strength were associated with differences in average RNFL thickness (R2 = 0.19; P < .0001). CONCLUSIONS: Even under optimal testing conditions, scan quality can adversely effect the ability to detect change over time. Therefore, caution is warranted when detecting glaucomatous progression using scan series of different quality. Careful overall assessment of quadrants and average RNFL thickness measurements is suggested to help identify scan misalignment.

Duke Scholars

Published In

Am J Ophthalmol

DOI

EISSN

1879-1891

Publication Date

August 2009

Volume

148

Issue

2

Start / End Page

249 / 255.e1

Location

United States

Related Subject Headings

  • Tomography, Optical Coherence
  • Signal Processing, Computer-Assisted
  • Retrospective Studies
  • Retinal Ganglion Cells
  • Reproducibility of Results
  • Optic Disk
  • Ophthalmology & Optometry
  • Nerve Fibers
  • Middle Aged
  • Male
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Vizzeri, G., Bowd, C., Medeiros, F. A., Weinreb, R. N., & Zangwill, L. M. (2009). Effect of signal strength and improper alignment on the variability of stratus optical coherence tomography retinal nerve fiber layer thickness measurements. Am J Ophthalmol, 148(2), 249-255.e1. https://doi.org/10.1016/j.ajo.2009.03.002
Vizzeri, Gianmarco, Christopher Bowd, Felipe A. Medeiros, Robert N. Weinreb, and Linda M. Zangwill. “Effect of signal strength and improper alignment on the variability of stratus optical coherence tomography retinal nerve fiber layer thickness measurements.Am J Ophthalmol 148, no. 2 (August 2009): 249-255.e1. https://doi.org/10.1016/j.ajo.2009.03.002.
Vizzeri, Gianmarco, et al. “Effect of signal strength and improper alignment on the variability of stratus optical coherence tomography retinal nerve fiber layer thickness measurements.Am J Ophthalmol, vol. 148, no. 2, Aug. 2009, pp. 249-255.e1. Pubmed, doi:10.1016/j.ajo.2009.03.002.
Journal cover image

Published In

Am J Ophthalmol

DOI

EISSN

1879-1891

Publication Date

August 2009

Volume

148

Issue

2

Start / End Page

249 / 255.e1

Location

United States

Related Subject Headings

  • Tomography, Optical Coherence
  • Signal Processing, Computer-Assisted
  • Retrospective Studies
  • Retinal Ganglion Cells
  • Reproducibility of Results
  • Optic Disk
  • Ophthalmology & Optometry
  • Nerve Fibers
  • Middle Aged
  • Male