Skip to main content
Journal cover image

Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography.

Publication ,  Journal Article
Medeiros, FA; Zangwill, LM; Bowd, C; Vessani, RM; Susanna, R; Weinreb, RN
Published in: Am J Ophthalmol
January 2005

PURPOSE: To compare the ability of optical coherence tomography retinal nerve fiber layer (RNFL), optic nerve head, and macular thickness parameters to differentiate between healthy eyes and eyes with glaucomatous visual field loss. DESIGN: Observational case-control study. METHODS: Eighty-eight patients with glaucoma and 78 healthy subjects were included. All patients underwent ONH, RNFL thickness, and macular thickness scans with Stratus OCT during the same visit. ROC curves and sensitivities at fixed specificities were calculated for each parameter. A discriminant analysis was performed to develop a linear discriminant function designed to identify and combine the best parameters. This LDF was subsequently tested on an independent sample consisting of 63 eyes of 63 subjects (27 glaucomatous and 36 healthy individuals) from a different geographic area. RESULTS: No statistically significant difference was found between the areas under the ROC curves (AUC) for the RNFL thickness parameter with the largest AUC (inferior thickness, AUC = 0.91) and the ONH parameter with largest AUC (cup/disk area ratio, AUC = 0.88) (P = .28). The RNFL parameter inferior thickness had a significantly larger AUC than the macular thickness parameter with largest AUC (inferior outer macular thickness, AUC = 0.81) (P = .004). A combination of selected RNFL and ONH parameters resulted in the best classification function for glaucoma detection with an AUC of 0.97 when applied to the independent sample. CONCLUSIONS: RNFL and ONH measurements had the best discriminating performance among the several Stratus OCT parameters. A combination of ONH and RNFL parameters improved the diagnostic accuracy for glaucoma detection using this instrument.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Am J Ophthalmol

DOI

ISSN

0002-9394

Publication Date

January 2005

Volume

139

Issue

1

Start / End Page

44 / 55

Location

United States

Related Subject Headings

  • Tomography, Optical Coherence
  • Sensitivity and Specificity
  • Retinal Ganglion Cells
  • Reproducibility of Results
  • ROC Curve
  • Optic Disk
  • Ophthalmology & Optometry
  • Nerve Fibers
  • Macula Lutea
  • Intraocular Pressure
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Medeiros, F. A., Zangwill, L. M., Bowd, C., Vessani, R. M., Susanna, R., & Weinreb, R. N. (2005). Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography. Am J Ophthalmol, 139(1), 44–55. https://doi.org/10.1016/j.ajo.2004.08.069
Medeiros, Felipe A., Linda M. Zangwill, Christopher Bowd, Roberto M. Vessani, Remo Susanna, and Robert N. Weinreb. “Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography.Am J Ophthalmol 139, no. 1 (January 2005): 44–55. https://doi.org/10.1016/j.ajo.2004.08.069.
Medeiros FA, Zangwill LM, Bowd C, Vessani RM, Susanna R, Weinreb RN. Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography. Am J Ophthalmol. 2005 Jan;139(1):44–55.
Medeiros, Felipe A., et al. “Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography.Am J Ophthalmol, vol. 139, no. 1, Jan. 2005, pp. 44–55. Pubmed, doi:10.1016/j.ajo.2004.08.069.
Medeiros FA, Zangwill LM, Bowd C, Vessani RM, Susanna R, Weinreb RN. Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography. Am J Ophthalmol. 2005 Jan;139(1):44–55.
Journal cover image

Published In

Am J Ophthalmol

DOI

ISSN

0002-9394

Publication Date

January 2005

Volume

139

Issue

1

Start / End Page

44 / 55

Location

United States

Related Subject Headings

  • Tomography, Optical Coherence
  • Sensitivity and Specificity
  • Retinal Ganglion Cells
  • Reproducibility of Results
  • ROC Curve
  • Optic Disk
  • Ophthalmology & Optometry
  • Nerve Fibers
  • Macula Lutea
  • Intraocular Pressure