Skip to main content
Journal cover image

Quantitative determination of the partial oxygen pressure in the vitrectomized rabbit eye in vivo using 19F NMR.

Publication ,  Journal Article
Berkowitz, BA; Wilson, CA; Hatchell, DL; London, RE
Published in: Magn Reson Med
October 1991

We have quantitatively determined the PO2 within the vitreous space of the vitrectomized rabbit eye in vivo using 19F NMR and perfluorotributylamine (FTBA). The results of the present work are in good agreement with previous measurements of PO2 within the nonvitrectimized rabbit eye obtained using oxygen microelectrodes. In this study, good precision and accuracy were achieved by: (1) having minimal flow effects present, (2) optimizing the signal-to-noise through the use of neat FTBA and surface coil transmission and detection, and (3) performing an inversion-recovery pulse sequence, with adiabatic pulses, to optimize the dynamic range of the T1 experiment. Possible deleterious effects on the measured T1 due to the vitreal temperature gradient are discussed. To the best of our knowledge the results of this study demonstrate, for the first time, a quantitative determination of intraocular PO2 in vivo using 19F NMR and FTBA.

Duke Scholars

Published In

Magn Reson Med

DOI

ISSN

0740-3194

Publication Date

October 1991

Volume

21

Issue

2

Start / End Page

233 / 241

Location

United States

Related Subject Headings

  • Vitreous Body
  • Vitrectomy
  • Reproducibility of Results
  • Rabbits
  • Oxygen
  • Nuclear Medicine & Medical Imaging
  • Microelectrodes
  • Magnetic Resonance Spectroscopy
  • Intraocular Pressure
  • Humans
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Berkowitz, B. A., Wilson, C. A., Hatchell, D. L., & London, R. E. (1991). Quantitative determination of the partial oxygen pressure in the vitrectomized rabbit eye in vivo using 19F NMR. Magn Reson Med, 21(2), 233–241. https://doi.org/10.1002/mrm.1910210208
Berkowitz, B. A., C. A. Wilson, D. L. Hatchell, and R. E. London. “Quantitative determination of the partial oxygen pressure in the vitrectomized rabbit eye in vivo using 19F NMR.Magn Reson Med 21, no. 2 (October 1991): 233–41. https://doi.org/10.1002/mrm.1910210208.
Berkowitz BA, Wilson CA, Hatchell DL, London RE. Quantitative determination of the partial oxygen pressure in the vitrectomized rabbit eye in vivo using 19F NMR. Magn Reson Med. 1991 Oct;21(2):233–41.
Berkowitz, B. A., et al. “Quantitative determination of the partial oxygen pressure in the vitrectomized rabbit eye in vivo using 19F NMR.Magn Reson Med, vol. 21, no. 2, Oct. 1991, pp. 233–41. Pubmed, doi:10.1002/mrm.1910210208.
Berkowitz BA, Wilson CA, Hatchell DL, London RE. Quantitative determination of the partial oxygen pressure in the vitrectomized rabbit eye in vivo using 19F NMR. Magn Reson Med. 1991 Oct;21(2):233–241.
Journal cover image

Published In

Magn Reson Med

DOI

ISSN

0740-3194

Publication Date

October 1991

Volume

21

Issue

2

Start / End Page

233 / 241

Location

United States

Related Subject Headings

  • Vitreous Body
  • Vitrectomy
  • Reproducibility of Results
  • Rabbits
  • Oxygen
  • Nuclear Medicine & Medical Imaging
  • Microelectrodes
  • Magnetic Resonance Spectroscopy
  • Intraocular Pressure
  • Humans