Skip to main content

Practice Variation in Anticoagulation Prescription and Outcomes After Device-Detected Atrial Fibrillation.

Publication ,  Journal Article
Perino, AC; Fan, J; Askari, M; Heidenreich, PA; Keung, E; Raitt, MH; Piccini, JP; Ziegler, PD; Turakhia, MP
Published in: Circulation
May 28, 2019

BACKGROUND: Device-detected atrial fibrillation (AF) is associated with increased risk of stroke; however, there are no clearly defined thresholds of AF burden at which to initiate oral anticoagulation (OAC). We sought to describe OAC prescription practice variation in response to new device-detected AF and the association with outcomes. METHODS: We performed a retrospective cohort study using data from the Veterans Health Administration linked to remote monitoring data that included day-level AF burden. We included patients with cardiac implantable electronic devices and remote monitoring from 2011 to 2014, CHA2DS2-VASc score ≥2, and no prior stroke or OAC receipt in the preceding 2 years. We determined the proportion of patients prescribed OAC within 90 days after new device-detected AF across a range of AF thresholds (≥6 minutes to >24 hours) and examined site variation in OAC prescription. We used multivariable Cox proportional hazards regressions to determine the association of OAC prescription with stroke by device-detected AF burden. RESULTS: Among 10 212 patients with cardiac implantable electronic devices, 4570 (45%), 3969 (39%), 3263 (32%), and 2469 (24%) had device-detected AF >6 minutes, >1 hour, >6 hours, and >24 hours, respectively. For device-detected AF >1 hour, 1712 patients met inclusion criteria (72±10 years; 1.5% female; CHA2DS2-VASc score 4.0±1.4; HAS-BLED score 2.6±1.1). The proportion receiving OAC varied based on device-detected AF burden (≥6 minutes: 272/2101 [13%]; >1 hour: 273/1712 [16%]; >6 hours: 263/1279 [21%]; >24 hours: 224/818 [27%]). Across 52 sites (N=1329 patients), there was substantial site-level variation in OAC prescription after device-detected AF >1 hour (median, 16%; range, 3%-67%; median odds ratio, 1.56 [95% credible interval, 1.49-1.71]). In adjusted models, OAC prescription after device-detected AF >24 hours was associated with reduced stroke risk (hazard ratio, 0.28; 95% CI, 0.10-0.81; P=0.02), although the propensity-adjusted model was significant when AF lasted at least 6 minutes. CONCLUSIONS: Among veterans with cardiac implantable electronic devices, device-detected AF is common. There is large practice variation in 90-day OAC initiation after new device-detected AF, with low rates of treatment overall, even for episodes that last >24 hours. The strongest association of OAC with reduction in stroke was observed after device-detected AF >24 hours. Randomized trials are needed to confirm these observational findings.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Circulation

DOI

EISSN

1524-4539

Publication Date

May 28, 2019

Volume

139

Issue

22

Start / End Page

2502 / 2512

Location

United States

Related Subject Headings

  • United States Department of Veterans Affairs
  • United States
  • Treatment Outcome
  • Time Factors
  • Stroke
  • Risk Factors
  • Risk Assessment
  • Retrospective Studies
  • Remote Sensing Technology
  • Predictive Value of Tests
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Perino, A. C., Fan, J., Askari, M., Heidenreich, P. A., Keung, E., Raitt, M. H., … Turakhia, M. P. (2019). Practice Variation in Anticoagulation Prescription and Outcomes After Device-Detected Atrial Fibrillation. Circulation, 139(22), 2502–2512. https://doi.org/10.1161/CIRCULATIONAHA.118.038988
Perino, Alexander C., Jun Fan, Mariam Askari, Paul A. Heidenreich, Edmund Keung, Merritt H. Raitt, Jonathan P. Piccini, Paul D. Ziegler, and Mintu P. Turakhia. “Practice Variation in Anticoagulation Prescription and Outcomes After Device-Detected Atrial Fibrillation.Circulation 139, no. 22 (May 28, 2019): 2502–12. https://doi.org/10.1161/CIRCULATIONAHA.118.038988.
Perino AC, Fan J, Askari M, Heidenreich PA, Keung E, Raitt MH, et al. Practice Variation in Anticoagulation Prescription and Outcomes After Device-Detected Atrial Fibrillation. Circulation. 2019 May 28;139(22):2502–12.
Perino, Alexander C., et al. “Practice Variation in Anticoagulation Prescription and Outcomes After Device-Detected Atrial Fibrillation.Circulation, vol. 139, no. 22, May 2019, pp. 2502–12. Pubmed, doi:10.1161/CIRCULATIONAHA.118.038988.
Perino AC, Fan J, Askari M, Heidenreich PA, Keung E, Raitt MH, Piccini JP, Ziegler PD, Turakhia MP. Practice Variation in Anticoagulation Prescription and Outcomes After Device-Detected Atrial Fibrillation. Circulation. 2019 May 28;139(22):2502–2512.

Published In

Circulation

DOI

EISSN

1524-4539

Publication Date

May 28, 2019

Volume

139

Issue

22

Start / End Page

2502 / 2512

Location

United States

Related Subject Headings

  • United States Department of Veterans Affairs
  • United States
  • Treatment Outcome
  • Time Factors
  • Stroke
  • Risk Factors
  • Risk Assessment
  • Retrospective Studies
  • Remote Sensing Technology
  • Predictive Value of Tests