Skip to main content
construction release_alert
Scholars@Duke will be undergoing maintenance April 11-15. Some features may be unavailable during this time.
cancel

Ophthalmic diagnostics using optical coherence tomography

Publication ,  Conference
Izatt, JA; Hee, MR; Huang, D; Fujimoto, JG; Swanson, EA; Lin, CP; Shuman, JS; Puliafito, CA
Published in: Proceedings of SPIE - The International Society for Optical Engineering
June 24, 1993

We present a new technique for coherent optical imaging of ocular structure based on optical coherence tomography (OCT). OCT is a noncontact, noninvasive, tomographic imaging technique with superior spatial resolution to ultrasound (< 20 μm) and high sensitivity (100 dB dynamic range). We have used OCT to perform direct imaging of ocular structure in the anterior and posterior segments of human eyes in vitro and in vivo. In the anterior segment, we have measured corneal thickness and profile, anterior chamber depth and angle, and iris thickness and profile. These and other possible measurements have potential applications in diagnosis of pathologies of the cornea, angle, and iris, as well as in noncontact biometry for applications in cataract and corneal refractive surgeries. In the posterior segment, we have obtained high-resolution images of retinal structure in human subjects in vivo. These images demonstrate higher resolution than available with any other existing technique, and include characterization of optic disk morphology and topology. These measurements have potential applications in early diagnosis and assessment of glaucoma and other retinal diseases.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Proceedings of SPIE - The International Society for Optical Engineering

DOI

EISSN

1996-756X

ISSN

0277-786X

Publication Date

June 24, 1993

Volume

1877

Start / End Page

136 / 144

Related Subject Headings

  • 5102 Atomic, molecular and optical physics
  • 4009 Electronics, sensors and digital hardware
  • 4006 Communications engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Izatt, J. A., Hee, M. R., Huang, D., Fujimoto, J. G., Swanson, E. A., Lin, C. P., … Puliafito, C. A. (1993). Ophthalmic diagnostics using optical coherence tomography. In Proceedings of SPIE - The International Society for Optical Engineering (Vol. 1877, pp. 136–144). https://doi.org/10.1117/12.147520
Izatt, J. A., M. R. Hee, D. Huang, J. G. Fujimoto, E. A. Swanson, C. P. Lin, J. S. Shuman, and C. A. Puliafito. “Ophthalmic diagnostics using optical coherence tomography.” In Proceedings of SPIE - The International Society for Optical Engineering, 1877:136–44, 1993. https://doi.org/10.1117/12.147520.
Izatt JA, Hee MR, Huang D, Fujimoto JG, Swanson EA, Lin CP, et al. Ophthalmic diagnostics using optical coherence tomography. In: Proceedings of SPIE - The International Society for Optical Engineering. 1993. p. 136–44.
Izatt, J. A., et al. “Ophthalmic diagnostics using optical coherence tomography.” Proceedings of SPIE - The International Society for Optical Engineering, vol. 1877, 1993, pp. 136–44. Scopus, doi:10.1117/12.147520.
Izatt JA, Hee MR, Huang D, Fujimoto JG, Swanson EA, Lin CP, Shuman JS, Puliafito CA. Ophthalmic diagnostics using optical coherence tomography. Proceedings of SPIE - The International Society for Optical Engineering. 1993. p. 136–144.

Published In

Proceedings of SPIE - The International Society for Optical Engineering

DOI

EISSN

1996-756X

ISSN

0277-786X

Publication Date

June 24, 1993

Volume

1877

Start / End Page

136 / 144

Related Subject Headings

  • 5102 Atomic, molecular and optical physics
  • 4009 Electronics, sensors and digital hardware
  • 4006 Communications engineering