Skip to main content
Journal cover image

Holmium:Yttrium-Aluminum-Garnet Laser Pulse Type Affects Irrigation Temperatures in a Benchtop Ureteral Model.

Publication ,  Journal Article
Winship, B; Terry, R; Boydston, K; Carlos, E; Wollin, D; Peters, C; Li, J; Preminger, G; Lipkin, M
Published in: J Endourol
November 2019

Introduction: MOSES™ technology is a holmium:yttrium-aluminum-garnet laser pulse mode shown to minimize stone retropulsion. This may facilitate lithotripsy at higher power settings. However, power and heat production are proportional, and temperatures capable of tissue injury may occur during ureteroscopic lithotripsy. Although previous in vitro studies demonstrate the importance of irrigation and activation time on heat production, the impact of pulse type has not been evaluated. Methods: A flexible ureteroscope with a 365 μm laser fiber was placed in an 11/13 F access sheath inserted into a 50 mL saline bag to simulate a ureter, renal pelvis, and antegrade irrigant flow. A thermocouple was placed adjacent to the laser tip, and the laser fired for 30 seconds at 0.6 J/6 Hz, 0.8 J/8 Hz, 1 J/10 Hz, 1 J/20 Hz, and 0.2 J/70 Hz at irrigation pressure of 100 mmHg. Four runs were tested per setting using short pulse, long pulse (LP), MOSES-contact (MC), and MOSES-distance (MD) modes. The mean temperature changes (dT) were compared and thermal dose was calculated in cumulative equivalent minutes at 43°C (CEM43) using an adjusted baseline of 37°C. CEM43 ≥ 120 minutes was considered the tissue injury threshold. Results: At 0.8 J/8 Hz, LP produced the greatest dT, significantly higher than MC (p = 0.041). CEM43 did not exceed the injury threshold. At 1 J/10 Hz, dT was significantly higher for LP versus MC and MD (p = 0.024 and 0.045, respectively). Thermal dose remained below the injury threshold. No differences in dT were seen between pulse types at 0.6 J/6 Hz, 0.2 J/70 Hz, or 1 J/20 Hz. At 1 J/20 Hz, thermal dose exceeded the injury threshold for all pulse types within 3 seconds. Conclusions: Laser pulse type and length seemed to impact heat production in our ureteral model. LP produced significantly greater temperatures at 0.8 J/8 Hz and 1 J/10 Hz relative to MOSES settings. Fortunately, thermal dose remained safe at these settings. Both LP and MOSES technology have been shown to reduce stone retropulsion. At power ≤10 W, the latter may confer this advantage with decreased heat production.

Duke Scholars

Published In

J Endourol

DOI

EISSN

1557-900X

Publication Date

November 2019

Volume

33

Issue

11

Start / End Page

896 / 901

Location

United States

Related Subject Headings

  • Yttrium
  • Urology & Nephrology
  • Ureteroscopy
  • Ureteroscopes
  • Ureteral Calculi
  • Ureter
  • Temperature
  • Models, Anatomic
  • Lithotripsy, Laser
  • Lasers, Solid-State
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Winship, B., Terry, R., Boydston, K., Carlos, E., Wollin, D., Peters, C., … Lipkin, M. (2019). Holmium:Yttrium-Aluminum-Garnet Laser Pulse Type Affects Irrigation Temperatures in a Benchtop Ureteral Model. J Endourol, 33(11), 896–901. https://doi.org/10.1089/end.2019.0496
Winship, Brenton, Russell Terry, Kohldon Boydston, Evan Carlos, Daniel Wollin, Chloe Peters, Jingqiu Li, Glenn Preminger, and Michael Lipkin. “Holmium:Yttrium-Aluminum-Garnet Laser Pulse Type Affects Irrigation Temperatures in a Benchtop Ureteral Model.J Endourol 33, no. 11 (November 2019): 896–901. https://doi.org/10.1089/end.2019.0496.
Winship B, Terry R, Boydston K, Carlos E, Wollin D, Peters C, et al. Holmium:Yttrium-Aluminum-Garnet Laser Pulse Type Affects Irrigation Temperatures in a Benchtop Ureteral Model. J Endourol. 2019 Nov;33(11):896–901.
Winship, Brenton, et al. “Holmium:Yttrium-Aluminum-Garnet Laser Pulse Type Affects Irrigation Temperatures in a Benchtop Ureteral Model.J Endourol, vol. 33, no. 11, Nov. 2019, pp. 896–901. Pubmed, doi:10.1089/end.2019.0496.
Winship B, Terry R, Boydston K, Carlos E, Wollin D, Peters C, Li J, Preminger G, Lipkin M. Holmium:Yttrium-Aluminum-Garnet Laser Pulse Type Affects Irrigation Temperatures in a Benchtop Ureteral Model. J Endourol. 2019 Nov;33(11):896–901.
Journal cover image

Published In

J Endourol

DOI

EISSN

1557-900X

Publication Date

November 2019

Volume

33

Issue

11

Start / End Page

896 / 901

Location

United States

Related Subject Headings

  • Yttrium
  • Urology & Nephrology
  • Ureteroscopy
  • Ureteroscopes
  • Ureteral Calculi
  • Ureter
  • Temperature
  • Models, Anatomic
  • Lithotripsy, Laser
  • Lasers, Solid-State