Comparison of thermal coagulation profiles for bipolar forceps with different cooling mechanisms in a porcine model of spinal surgery.

Publication ,  Journal Article
Chen, RK; Than, KD; Wang, AC; Park, P; Shih, AJ
Published in: Surg Neurol Int
2013

BACKGROUND: Coagulation accomplished using bipolar forceps is common in neurosurgery. Control of thermal spread from the forceps tips into surrounding neural tissues is a persistent concern, as neural tissues are especially vulnerable to heat injury. The purpose of our investigation was to compare the efficacy of cooling mechanisms for four different bipolar forceps and to understand thermal spread when coagulating vessels on the spinal cord. METHODS: Immediately following euthanasia, the dura mater of an ex vivo porcine model was opened to expose vessels on the spinal cord for coagulation. Temperature profiles were measured at generator power of 25 W and at fixed 5-second activation times. The bipolar forceps used in this study included regular stainless steel, titanium, heat-pipe embedded, and SILVERGlide forceps. Temperature was measured by micro-thermistor at the midpoint between the bipolar tips, and 1 and 2 mm away from the midpoint along the centerline. Statistical analysis was performed to evaluate temperature differences. RESULTS: Temperature profiles indicated that heat-pipe embedded forceps create the least amount of temperature increase and the highest normalized temperature decreasing slope after activation. The decreasing slope of SILVERGlide forceps is slightly higher than that of regular stainless steel forceps. CONCLUSIONS: Bipolar forceps incorporating either heat-pipe embedded technology or SILVERGlide coating can effectively limit excessive thermal spread, thus decreasing potential injury to adjacent tissues when compared with standard stainless steel and titanium bipolar forceps. Of the two, heat-pipe embedded technology appeared safest, having better cooling efficiency at higher temperature.

Duke Scholars

Published In

Surg Neurol Int

DOI

ISSN

2229-5097

Publication Date

2013

Volume

4

Start / End Page

113

Location

United States

Related Subject Headings

  • 1109 Neurosciences
  • 1103 Clinical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Chen, R. K., Than, K. D., Wang, A. C., Park, P., & Shih, A. J. (2013). Comparison of thermal coagulation profiles for bipolar forceps with different cooling mechanisms in a porcine model of spinal surgery. Surg Neurol Int, 4, 113. https://doi.org/10.4103/2152-7806.117709
Chen, Roland K., Khoi D. Than, Anthony C. Wang, Paul Park, and Albert J. Shih. “Comparison of thermal coagulation profiles for bipolar forceps with different cooling mechanisms in a porcine model of spinal surgery.Surg Neurol Int 4 (2013): 113. https://doi.org/10.4103/2152-7806.117709.
Chen, Roland K., et al. “Comparison of thermal coagulation profiles for bipolar forceps with different cooling mechanisms in a porcine model of spinal surgery.Surg Neurol Int, vol. 4, 2013, p. 113. Pubmed, doi:10.4103/2152-7806.117709.

Published In

Surg Neurol Int

DOI

ISSN

2229-5097

Publication Date

2013

Volume

4

Start / End Page

113

Location

United States

Related Subject Headings

  • 1109 Neurosciences
  • 1103 Clinical Sciences