Skip to main content

Design and clinical evaluation of a high capacity digital image archival library and high speed network for the replacement of cinefilm in the cardiac angiography environment

Publication ,  Conference
Cusma, JT; Spero, LA; Groshong, BR; Cho, T; Bashore, TM
Published in: Proceedings of SPIE - The International Society for Optical Engineering
September 8, 1993

An economical and practical digital solution for the replacement of 35mm cinefilm as the archive media in the cardiac x-ray imaging environment has remained lacking to date due to the demanding requirements of high capacity, high acquisition rate, high transfer rate, and a need for application in a distributed environment. A clinical digital image library and network based on the D2 digital video format has been installed in the Duke University Cardiac Catheterization Laboratory. The system architecture includes a central image library with digital video recorders and robotic tape retrieval, 3 acquisition stations, and remote review stations connected via a serial image network. The library has a capacity for over 20,000 Gigabytes of uncompressed image data, equivalent to records for approximately 20,000 patients. Image acquisition in the clinical laboratories is via a real-time digital interface between the digital angiography system and a local digital recorder. Images are transferred to the library over the serial network at a rate of 14.3 Mbytes/sec and permanently stored for later review. The image library and network are currently undergoing a clinical comparison with cinefilm for visual and quantitative assessment of coronary artery disease. At the conclusion of the evaluation, the configuration will be expanded to include 4 additional catheterization laboratories and remote review stations throughout the hospital.

Duke Scholars

Published In

Proceedings of SPIE - The International Society for Optical Engineering

DOI

EISSN

1996-756X

ISSN

0277-786X

Publication Date

September 8, 1993

Volume

1899

Start / End Page

413 / 422
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Cusma, J. T., Spero, L. A., Groshong, B. R., Cho, T., & Bashore, T. M. (1993). Design and clinical evaluation of a high capacity digital image archival library and high speed network for the replacement of cinefilm in the cardiac angiography environment. In Proceedings of SPIE - The International Society for Optical Engineering (Vol. 1899, pp. 413–422). https://doi.org/10.1117/12.152917
Cusma, J. T., L. A. Spero, B. R. Groshong, T. Cho, and T. M. Bashore. “Design and clinical evaluation of a high capacity digital image archival library and high speed network for the replacement of cinefilm in the cardiac angiography environment.” In Proceedings of SPIE - The International Society for Optical Engineering, 1899:413–22, 1993. https://doi.org/10.1117/12.152917.
Cusma JT, Spero LA, Groshong BR, Cho T, Bashore TM. Design and clinical evaluation of a high capacity digital image archival library and high speed network for the replacement of cinefilm in the cardiac angiography environment. In: Proceedings of SPIE - The International Society for Optical Engineering. 1993. p. 413–22.
Cusma, J. T., et al. “Design and clinical evaluation of a high capacity digital image archival library and high speed network for the replacement of cinefilm in the cardiac angiography environment.” Proceedings of SPIE - The International Society for Optical Engineering, vol. 1899, 1993, pp. 413–22. Scopus, doi:10.1117/12.152917.
Cusma JT, Spero LA, Groshong BR, Cho T, Bashore TM. Design and clinical evaluation of a high capacity digital image archival library and high speed network for the replacement of cinefilm in the cardiac angiography environment. Proceedings of SPIE - The International Society for Optical Engineering. 1993. p. 413–422.

Published In

Proceedings of SPIE - The International Society for Optical Engineering

DOI

EISSN

1996-756X

ISSN

0277-786X

Publication Date

September 8, 1993

Volume

1899

Start / End Page

413 / 422