PURPOSE: To compare the efficacy of two 18-gauge core needle biopsy systems, the Achieve® (Merit Medical) and the Marquee® (BD Bard), using an ex-vivo animal liver model and retrospective review of clinical experience. METHODS: Sixty ex-vivo liver biopsy samples were obtained using the Achieve® (n = 30) and the Marquee® (n = 30) needles. In addition, 20 liver biopsy samples from 20 patients obtained using the Achieve® (n = 10) and Marquee® (n = 10) were compared retrospectively. One pathologist, blinded to needle type, recorded total core length and the number of complete portal triads. Ex vivo measurements were compared using mixed effects linear, logistic, and ordinal regression. In vivo measurements were compared using Student's t-test. RESULTS: For the Achieve® and Marquee® needles, the mean(SD) total core length (mm) of ex vivo samples was 11.0(3.3) and 12.6(3.4), respectively (P = 0.069) and the adequacy rate was 23.3% and 50%, respectively (P = 0.04). Mean number of portal triads of ex vivo samples was 7.2(2.9) and 8.6(3.8), respectively (P = 0.13), and the adequacy rate was 73.3% and 83.3%, respectively (P = 0.32). For in vivo samples, the Achieve® and Marquee® needles demonstrates mean(SD) total core length (mm) of 24.6(7.1) and 32.0(4.6), respectively (P = 0.01), adequacy rate (P = 0.06). Mean number of portal triads was 14.9(4.8) and 19.6(4.1), respectively (P = 0.03), adequacy rate (P = 0.47). CONCLUSIONS: Slightly longer core biopsies were obtained with the Marquee® needle compared with the Achieve® needle. Early clinical experience demonstrates no significant difference in sample adequacy rates. Both needle types can be expected to provide adequate samples for pathologic assessment of liver tissue.

Duke Scholars

Published In

Clin Imaging

DOI

EISSN

1873-4499

Publication Date

May 2020

Volume

61

Start / End Page

36 / 42

Location

United States

Related Subject Headings

  • Ultrasonography, Interventional
  • Ultrasonography
  • Retrospective Studies
  • Nuclear Medicine & Medical Imaging
  • Needles
  • Middle Aged
  • Male
  • Liver
  • Image-Guided Biopsy
  • Humans
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Ho, L. M., Pendse, A. A., Ronald, J., Luciano, M., Marin, D., Jaffe, T. A., & Nelson, R. C. (2020). Ultrasound-guided non-targeted liver core biopsy: comparison of the efficacy of two different core needle biopsy systems using an ex-vivo animal model and retrospective review of clinical experience. Clin Imaging, 61, 36–42. https://doi.org/10.1016/j.clinimag.2020.01.005
Ho, Lisa M., Avani A. Pendse, James Ronald, Marcus Luciano, Daniele Marin, Tracy A. Jaffe, and Rendon C. Nelson. “Ultrasound-guided non-targeted liver core biopsy: comparison of the efficacy of two different core needle biopsy systems using an ex-vivo animal model and retrospective review of clinical experience.Clin Imaging 61 (May 2020): 36–42. https://doi.org/10.1016/j.clinimag.2020.01.005.
Journal cover image

Published In

Clin Imaging

DOI

EISSN

1873-4499

Publication Date

May 2020

Volume

61

Start / End Page

36 / 42

Location

United States

Related Subject Headings

  • Ultrasonography, Interventional
  • Ultrasonography
  • Retrospective Studies
  • Nuclear Medicine & Medical Imaging
  • Needles
  • Middle Aged
  • Male
  • Liver
  • Image-Guided Biopsy
  • Humans