Skip to main content

Long-Term Safety and Efficacy of Durable Polymer Cobalt-Chromium Everolimus-Eluting Stents in Patients at High Bleeding Risk: A Patient-Level Stratified Analysis From Four Postapproval Studies.

Publication ,  Journal Article
Sorrentino, S; Claessen, BE; Chandiramani, R; Guedeney, P; Vogel, B; Baber, U; Rau, V; Wang, J; Krucoff, M; Kozuma, K; Ge, J; Seth, A; Liu, Y ...
Published in: Circulation
March 17, 2020

BACKGROUND: Long-term outcomes in patients at high bleeding risk (HBR) undergoing percutaneous coronary intervention with a drug-eluting stent are unclear. Therefore, we aimed to evaluate long-term adverse events in HBR patients undergoing percutaneous coronary intervention with cobalt-chromium everolimus-eluting stent implantation. METHODS: We analyzed stratified data from 4 all-comers postapproval registries. Patients with at least 1 of the following criteria were categorized as HBR: age ≥75 years, history of major bleeding (MB), history of stroke, chronic oral anticoagulant use, chronic kidney disease, anemia, or thrombocytopenia. Additionally, in a separate analysis, patients were categorized according to the recently published Academic Research Consortium HBR criteria. The Kaplan-Meier method was used for time-to-event analyses. Coronary thrombotic events (CTE) included myocardial infarction or definite/probable stent thrombosis. MB was defined according to the TIMI (Thrombolysis in Myocardial Infarction) or GUSTO (Global Use of Strategies to Open Occluded Coronary Arteries) scales. Impact of CTE and MB on subsequent risk of mortality was assessed using multivariable Cox regression with MB and CTE included as time-updated covariates. RESULTS: Of the total 10 502 patients included, 3507 (33%) were identified as HBR. Compared with non-HBR patients, those at HBR had more comorbidities, higher lesion complexity, and a higher risk of 4-year mortality (Hazard Ratio [HR] 4.38 [95% CI, 3.76-5.11]). Results were qualitatively similar when using Academic Research Consortium criteria to define HBR. Risk of mortality was increased after CTE (HR 5.02 [95% CI, 3.93-6.41]), as well as after MB (HR 4.92 [95% CI, 3.82-6.35]). Of note, this effect was consistent across the spectrum of bleeding risk (P-interaction test 0.97 and 0.06, respectively). CONCLUSIONS: Compared with the non-HBR population, HBR patients experienced worse 4-year outcomes after percutaneous coronary intervention with cobalt-chromium everolimus-eluting stent. Both CTE and MB had a significant impact on subsequent risk of mortality irrespective of bleeding risk.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Circulation

DOI

EISSN

1524-4539

Publication Date

March 17, 2020

Volume

141

Issue

11

Start / End Page

891 / 901

Location

United States

Related Subject Headings

  • Treatment Outcome
  • Smoking
  • Registries
  • Prospective Studies
  • Proportional Hazards Models
  • Prevalence
  • Polymers
  • Platelet Aggregation Inhibitors
  • Percutaneous Coronary Intervention
  • Myocardial Infarction
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Sorrentino, S., Claessen, B. E., Chandiramani, R., Guedeney, P., Vogel, B., Baber, U., … Mehran, R. (2020). Long-Term Safety and Efficacy of Durable Polymer Cobalt-Chromium Everolimus-Eluting Stents in Patients at High Bleeding Risk: A Patient-Level Stratified Analysis From Four Postapproval Studies. Circulation, 141(11), 891–901. https://doi.org/10.1161/CIRCULATIONAHA.119.041619
Sorrentino, Sabato, Bimmer E. Claessen, Rishi Chandiramani, Paul Guedeney, Birgit Vogel, Usman Baber, Vinuta Rau, et al. “Long-Term Safety and Efficacy of Durable Polymer Cobalt-Chromium Everolimus-Eluting Stents in Patients at High Bleeding Risk: A Patient-Level Stratified Analysis From Four Postapproval Studies.Circulation 141, no. 11 (March 17, 2020): 891–901. https://doi.org/10.1161/CIRCULATIONAHA.119.041619.
Sorrentino, Sabato, et al. “Long-Term Safety and Efficacy of Durable Polymer Cobalt-Chromium Everolimus-Eluting Stents in Patients at High Bleeding Risk: A Patient-Level Stratified Analysis From Four Postapproval Studies.Circulation, vol. 141, no. 11, Mar. 2020, pp. 891–901. Pubmed, doi:10.1161/CIRCULATIONAHA.119.041619.
Sorrentino S, Claessen BE, Chandiramani R, Guedeney P, Vogel B, Baber U, Rau V, Wang J, Krucoff M, Kozuma K, Ge J, Seth A, Makkar R, Liu Y, Bangalore S, Bhatt DL, Angiolillo DJ, Saito S, Neumann F-J, Hermiller J, Valgimigli M, Mehran R. Long-Term Safety and Efficacy of Durable Polymer Cobalt-Chromium Everolimus-Eluting Stents in Patients at High Bleeding Risk: A Patient-Level Stratified Analysis From Four Postapproval Studies. Circulation. 2020 Mar 17;141(11):891–901.

Published In

Circulation

DOI

EISSN

1524-4539

Publication Date

March 17, 2020

Volume

141

Issue

11

Start / End Page

891 / 901

Location

United States

Related Subject Headings

  • Treatment Outcome
  • Smoking
  • Registries
  • Prospective Studies
  • Proportional Hazards Models
  • Prevalence
  • Polymers
  • Platelet Aggregation Inhibitors
  • Percutaneous Coronary Intervention
  • Myocardial Infarction