Skip to main content

Accuracy and efficiency of image-guided radiation therapy (IGRT) for preoperative partial breast radiosurgery.

Publication ,  Journal Article
Yoo, S; O'Daniel, J; Blitzblau, R; Yin, F-F; Horton, JK
Published in: J Radiosurg SBRT
2020

OBJECTIVE: To analyze and evaluate accuracy and efficiency of IGRT process for preoperative partial breast radiosurgery. METHODS: Patients were initially setup with skin marks and 5 steps were performed: (1) Initial orthogonal 2D kV images, (2) pre-treatment 3D CBCT images, (3) verification orthogonal 2D kV images, (4) treatment including mid-treatment 2D kV images (for the final 15 patients only), and (5) post-treatment orthogonal 2D kV or 3D CBCT images. Patient position was corrected at each step to align the biopsy clip and to verify surrounding soft tissue positioning. RESULTS: The mean combined vector magnitude shifts and standard deviations at the 5 imaging steps were (1) 0.96 ± 0.69, (2) 0.33 ± 0.40, (3) 0.05 ± 0.12, (4) 0.15 ± 0.17, and (5) 0.27 ± 0.24 in cm. The mean total IGRT time was 40.2 ± 13.2 minutes. Each step was shortened by 2 to 5 minutes with improvements implemented. Overall, improvements in the IGRT process reduced the mean total IGRT time by approximately 20 minutes. Clip visibility was improved by implementing oblique orthogonal images. CONCLUSION: Multiple imaging steps confirmed accurate patient positioning. Appropriate planning and imaging strategies improved the effectiveness and efficiency of the IGRT process for preoperative partial breast radiosurgery.

Duke Scholars

Published In

J Radiosurg SBRT

EISSN

2156-4647

Publication Date

2020

Volume

6

Issue

4

Start / End Page

295 / 301

Location

United States
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Yoo, S., O’Daniel, J., Blitzblau, R., Yin, F.-F., & Horton, J. K. (2020). Accuracy and efficiency of image-guided radiation therapy (IGRT) for preoperative partial breast radiosurgery. J Radiosurg SBRT, 6(4), 295–301.
Yoo, Sua, Jennifer O’Daniel, Rachel Blitzblau, Fang-Fang Yin, and Janet K. Horton. “Accuracy and efficiency of image-guided radiation therapy (IGRT) for preoperative partial breast radiosurgery.J Radiosurg SBRT 6, no. 4 (2020): 295–301.
Yoo S, O’Daniel J, Blitzblau R, Yin F-F, Horton JK. Accuracy and efficiency of image-guided radiation therapy (IGRT) for preoperative partial breast radiosurgery. J Radiosurg SBRT. 2020;6(4):295–301.
Yoo, Sua, et al. “Accuracy and efficiency of image-guided radiation therapy (IGRT) for preoperative partial breast radiosurgery.J Radiosurg SBRT, vol. 6, no. 4, 2020, pp. 295–301.
Yoo S, O’Daniel J, Blitzblau R, Yin F-F, Horton JK. Accuracy and efficiency of image-guided radiation therapy (IGRT) for preoperative partial breast radiosurgery. J Radiosurg SBRT. 2020;6(4):295–301.

Published In

J Radiosurg SBRT

EISSN

2156-4647

Publication Date

2020

Volume

6

Issue

4

Start / End Page

295 / 301

Location

United States