Clinical concordance with Image Gently guidelines for pediatric computed tomography: a study across 663,417 CT scans at 53 clinical facilities.

Publication ,  Journal Article
Smith, TB; Heil, J; Frush, DP; Samei, E
Published in: Pediatr Radiol
May 2021

BACKGROUND: Managing patient radiation dose in pediatric computed tomography (CT) examinations is essential. Some organizations, most notably Image Gently, have suggested techniques to lower dose to pediatric patients and mitigate risk while maintaining image quality. OBJECTIVE: We sought to validate whether institutions are observing Image Gently guidelines in practice. MATERIALS AND METHODS: Dose-relevant data from 663,417 abdomen-pelvis and chest CT scans were obtained from 53 facilities. Patients were assigned arbitrary age cohorts with a minimum size of n=12 patients in each age group, for statistical purposes. All pediatric (<19 years old) cohorts at a given facility were compared to the adult cohort by a Kruskal-Wallis test for each of the four scan parameters - (1) x-ray tube kilovoltage (kV), (2) tube-current-by-exposure-time product (tube mAs), (3) scan pitch and (4) tube rotation time - to assess whether the distribution of values in the pediatric cohorts differed from the adult cohort. The same was repeated with volume CT dose index (CTDIvol) and size-specific dose estimate (SSDE) to assess whether pediatric cohorts received less dose than adult cohorts. A P-value of <0.05 was deemed significant. RESULTS: Across the 150 pediatric cohorts, 134 had scan parameters that were more child-sized than their adult counterparts. In 128 of these 134 pediatric cohorts, the CTDIvol was less than the adult counterpart. In 111 of these 128 pediatric cohorts, the SSDE was less than the adult counterpart. CONCLUSION: The study reaffirms that in practice, Image Gently's suggestions of lowering tube mAs and peak kilovoltage are commonly employed and effective at reducing pediatric CT dose.

Duke Scholars

Published In

Pediatr Radiol

DOI

EISSN

1432-1998

Publication Date

May 2021

Volume

51

Issue

5

Start / End Page

800 / 810

Location

Germany

Related Subject Headings

  • Tomography, X-Ray Computed
  • Thorax
  • Radionuclide Imaging
  • Radiation Dosage
  • Nuclear Medicine & Medical Imaging
  • Humans
  • Child
  • Adult
  • 3213 Paediatrics
  • 3202 Clinical sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Smith, T. B., Heil, J., Frush, D. P., & Samei, E. (2021). Clinical concordance with Image Gently guidelines for pediatric computed tomography: a study across 663,417 CT scans at 53 clinical facilities. Pediatr Radiol, 51(5), 800–810. https://doi.org/10.1007/s00247-020-04909-5
Smith, Taylor Brunton, John Heil, Donald P. Frush, and Ehsan Samei. “Clinical concordance with Image Gently guidelines for pediatric computed tomography: a study across 663,417 CT scans at 53 clinical facilities.Pediatr Radiol 51, no. 5 (May 2021): 800–810. https://doi.org/10.1007/s00247-020-04909-5.
Smith, Taylor Brunton, et al. “Clinical concordance with Image Gently guidelines for pediatric computed tomography: a study across 663,417 CT scans at 53 clinical facilities.Pediatr Radiol, vol. 51, no. 5, May 2021, pp. 800–10. Pubmed, doi:10.1007/s00247-020-04909-5.
Journal cover image

Published In

Pediatr Radiol

DOI

EISSN

1432-1998

Publication Date

May 2021

Volume

51

Issue

5

Start / End Page

800 / 810

Location

Germany

Related Subject Headings

  • Tomography, X-Ray Computed
  • Thorax
  • Radionuclide Imaging
  • Radiation Dosage
  • Nuclear Medicine & Medical Imaging
  • Humans
  • Child
  • Adult
  • 3213 Paediatrics
  • 3202 Clinical sciences