Image quality of EOS low-dose radiography in comparison with conventional radiography for assessment of ventriculoperitoneal shunt integrity.

Publication ,  Journal Article
Monuszko, K; Malinzak, M; Yang, LZ; Niedzwiecki, D; Fuchs, H; Muh, CR; Gingrich, K; Lark, R; Thompson, EM
Published in: J Neurosurg Pediatr
January 8, 2021

OBJECTIVE: Patients with shunted hydrocephalus often accumulate high levels of radiation over their lifetimes during evaluation of hardware integrity. Current practice involves the use of a series of conventional radiographs for this purpose. Newer low-dose EOS radiography is currently used to evaluate scoliosis but has not been explored to evaluate shunt integrity on a large scale. The goal of this study was to compare the quality of imaging using EOS low-dose radiography to conventional radiography to evaluate shunt tubing. METHODS: A retrospective chart review was performed on 57 patients who previously had both conventional radiographs and low-dose EOS images of their cerebral shunt tubing from 2000 to 2018. Patient demographics (age, sex, type of shunt tubing, primary diagnosis) were collected. Conventional radiographic images and low-dose EOS images were independently analyzed by a neurosurgeon and neuroradiologist in three categories: image quality, delineation of shunt, and distinction of shunt compared to adjacent anatomy. RESULTS: All patients had shunted hydrocephalus due to spina bifida and Chiari type II malformation. Ratings of EOS and conventional radiographic images by both raters did not differ significantly in terms of image quality (rater 1, p = 0.499; rater 2, p = 0.578) or delineation of shunt (p = 0.107 and p = 0.256). Conventional radiographic images received significantly higher ratings than EOS on the ability to distinguish the shunt versus adjacent anatomy by rater 1 (p = 0.039), but not by rater 2 (p = 0.149). The overall score of the three categories combined was not significantly different between EOS and conventional radiography (rater 1, p = 0.818; rater 2, p = 0.186). In terms of cost, an EOS image was less costly than a conventional radiography shunt series ($236-$366 and $1300-$1547, respectively). The radiation dose was also lower for EOS images, with an effective dose of 0.086-0.140 mSv compared to approximately 1.6 mSv for a similar field of view with conventional radiography. CONCLUSIONS: The image quality of low-dose EOS radiography does not significantly differ from conventional radiography for the evaluation of cerebral shunts. In addition, EOS affords a much lower radiation dose and a lower cost.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

J Neurosurg Pediatr

DOI

EISSN

1933-0715

Publication Date

January 8, 2021

Volume

27

Issue

4

Start / End Page

375 / 381

Location

United States

Related Subject Headings

  • Young Adult
  • Ventriculoperitoneal Shunt
  • Retrospective Studies
  • Radiography
  • Radiation Dosage
  • Neurology & Neurosurgery
  • Male
  • Hydrocephalus
  • Humans
  • Female
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Monuszko, K., Malinzak, M., Yang, L. Z., Niedzwiecki, D., Fuchs, H., Muh, C. R., … Thompson, E. M. (2021). Image quality of EOS low-dose radiography in comparison with conventional radiography for assessment of ventriculoperitoneal shunt integrity. J Neurosurg Pediatr, 27(4), 375–381. https://doi.org/10.3171/2020.8.PEDS20428
Monuszko, Karen, Michael Malinzak, Lexie Zidanyue Yang, Donna Niedzwiecki, Herbert Fuchs, Carrie R. Muh, Krista Gingrich, Robert Lark, and Eric M. Thompson. “Image quality of EOS low-dose radiography in comparison with conventional radiography for assessment of ventriculoperitoneal shunt integrity.J Neurosurg Pediatr 27, no. 4 (January 8, 2021): 375–81. https://doi.org/10.3171/2020.8.PEDS20428.
Monuszko K, Malinzak M, Yang LZ, Niedzwiecki D, Fuchs H, Muh CR, et al. Image quality of EOS low-dose radiography in comparison with conventional radiography for assessment of ventriculoperitoneal shunt integrity. J Neurosurg Pediatr. 2021 Jan 8;27(4):375–81.
Monuszko, Karen, et al. “Image quality of EOS low-dose radiography in comparison with conventional radiography for assessment of ventriculoperitoneal shunt integrity.J Neurosurg Pediatr, vol. 27, no. 4, Jan. 2021, pp. 375–81. Pubmed, doi:10.3171/2020.8.PEDS20428.
Monuszko K, Malinzak M, Yang LZ, Niedzwiecki D, Fuchs H, Muh CR, Gingrich K, Lark R, Thompson EM. Image quality of EOS low-dose radiography in comparison with conventional radiography for assessment of ventriculoperitoneal shunt integrity. J Neurosurg Pediatr. 2021 Jan 8;27(4):375–381.

Published In

J Neurosurg Pediatr

DOI

EISSN

1933-0715

Publication Date

January 8, 2021

Volume

27

Issue

4

Start / End Page

375 / 381

Location

United States

Related Subject Headings

  • Young Adult
  • Ventriculoperitoneal Shunt
  • Retrospective Studies
  • Radiography
  • Radiation Dosage
  • Neurology & Neurosurgery
  • Male
  • Hydrocephalus
  • Humans
  • Female