Aperture weighting functions are critical design parameters in the development of ultrasound systems because beam characteristics determine the contrast and point resolution of the final image. In previous work by our group, we developed a general apodization design method that optimizes a broadband imaging system's contrast resolution performance [1, 2]. In that algorithm we used constrained least squares (CLS) techniques and a linear algebra formulation of the system point spread function (PSF) as a function of the scalar aperture weights. In this work we replace the receive aperture weights with individual channel finite impulse response (FIR) filters to produce PSFs with narrower mainlobe widths and lower sidelobe levels compared to PSFs produced with conventional apodization functions. Our approach minimizes the energy of the PSF outside a defined boundary while imposing a quadratic constraint on the energy of the PSF inside the boundary. We present simulation results showing that FIR filters of modest tap lengths (3-7) can yield marked improvement in image contrast and point resolution. Specifically we show results that 7-tap FIR filters can reduce sidelobe and grating lobe energy by 30dB and improve cystic contrast [3] by as much as 20dB compared to conventional apodization profiles. We also show experimental results where multi-tap FIR filters decrease sidelobe energy in the resulting 2D PSF and maintain a narrow mainlobe. Our algorithm has the potential to significantly improve ultrasound beamforming in any application where the system response is well characterized. Furthermore, this algorithm can be used to increase contrast and resolution in novel receive only beamforming systems [4, 5].

Duke Scholars

Published In

Progress in Biomedical Optics and Imaging - Proceedings of SPIE

DOI

ISSN

1605-7422

ISBN

9780819466310

Publication Date

January 1, 2007

Volume

6513
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Guenther, D. A., & Walker, W. F. (2007). Receive channel FIR filters for enhanced contrast in medical ultrasound. In Progress in Biomedical Optics and Imaging - Proceedings of SPIE (Vol. 6513). https://doi.org/10.1117/12.709702
Guenther, D. A., and W. F. Walker. “Receive channel FIR filters for enhanced contrast in medical ultrasound.” In Progress in Biomedical Optics and Imaging - Proceedings of SPIE, Vol. 6513, 2007. https://doi.org/10.1117/12.709702.
Guenther DA, Walker WF. Receive channel FIR filters for enhanced contrast in medical ultrasound. In: Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2007.
Guenther, D. A., and W. F. Walker. “Receive channel FIR filters for enhanced contrast in medical ultrasound.” Progress in Biomedical Optics and Imaging - Proceedings of SPIE, vol. 6513, 2007. Scopus, doi:10.1117/12.709702.
Guenther DA, Walker WF. Receive channel FIR filters for enhanced contrast in medical ultrasound. Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2007.

Published In

Progress in Biomedical Optics and Imaging - Proceedings of SPIE

DOI

ISSN

1605-7422

ISBN

9780819466310

Publication Date

January 1, 2007

Volume

6513