Skip to main content

Practical no-gold-standard evaluation framework for quantitative imaging methods: application to lesion segmentation in positron emission tomography.

Publication ,  Journal Article
Jha, AK; Mena, E; Caffo, B; Ashrafinia, S; Rahmim, A; Frey, E; Subramaniam, RM
Published in: J Med Imaging (Bellingham)
January 2017

Recently, a class of no-gold-standard (NGS) techniques have been proposed to evaluate quantitative imaging methods using patient data. These techniques provide figures of merit (FoMs) quantifying the precision of the estimated quantitative value without requiring repeated measurements and without requiring a gold standard. However, applying these techniques to patient data presents several practical difficulties including assessing the underlying assumptions, accounting for patient-sampling-related uncertainty, and assessing the reliability of the estimated FoMs. To address these issues, we propose statistical tests that provide confidence in the underlying assumptions and in the reliability of the estimated FoMs. Furthermore, the NGS technique is integrated within a bootstrap-based methodology to account for patient-sampling-related uncertainty. The developed NGS framework was applied to evaluate four methods for segmenting lesions from F-Fluoro-2-deoxyglucose positron emission tomography images of patients with head-and-neck cancer on the task of precisely measuring the metabolic tumor volume. The NGS technique consistently predicted the same segmentation method as the most precise method. The proposed framework provided confidence in these results, even when gold-standard data were not available. The bootstrap-based methodology indicated improved performance of the NGS technique with larger numbers of patient studies, as was expected, and yielded consistent results as long as data from more than 80 lesions were available for the analysis.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

J Med Imaging (Bellingham)

DOI

ISSN

2329-4302

Publication Date

January 2017

Volume

4

Issue

1

Start / End Page

011011

Location

United States

Related Subject Headings

  • 4003 Biomedical engineering
  • 3202 Clinical sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Jha, A. K., Mena, E., Caffo, B., Ashrafinia, S., Rahmim, A., Frey, E., & Subramaniam, R. M. (2017). Practical no-gold-standard evaluation framework for quantitative imaging methods: application to lesion segmentation in positron emission tomography. J Med Imaging (Bellingham), 4(1), 011011. https://doi.org/10.1117/1.JMI.4.1.011011
Jha, Abhinav K., Esther Mena, Brian Caffo, Saeed Ashrafinia, Arman Rahmim, Eric Frey, and Rathan M. Subramaniam. “Practical no-gold-standard evaluation framework for quantitative imaging methods: application to lesion segmentation in positron emission tomography.J Med Imaging (Bellingham) 4, no. 1 (January 2017): 011011. https://doi.org/10.1117/1.JMI.4.1.011011.
Jha AK, Mena E, Caffo B, Ashrafinia S, Rahmim A, Frey E, et al. Practical no-gold-standard evaluation framework for quantitative imaging methods: application to lesion segmentation in positron emission tomography. J Med Imaging (Bellingham). 2017 Jan;4(1):011011.
Jha, Abhinav K., et al. “Practical no-gold-standard evaluation framework for quantitative imaging methods: application to lesion segmentation in positron emission tomography.J Med Imaging (Bellingham), vol. 4, no. 1, Jan. 2017, p. 011011. Pubmed, doi:10.1117/1.JMI.4.1.011011.
Jha AK, Mena E, Caffo B, Ashrafinia S, Rahmim A, Frey E, Subramaniam RM. Practical no-gold-standard evaluation framework for quantitative imaging methods: application to lesion segmentation in positron emission tomography. J Med Imaging (Bellingham). 2017 Jan;4(1):011011.

Published In

J Med Imaging (Bellingham)

DOI

ISSN

2329-4302

Publication Date

January 2017

Volume

4

Issue

1

Start / End Page

011011

Location

United States

Related Subject Headings

  • 4003 Biomedical engineering
  • 3202 Clinical sciences